background image

Hitec RCD USA, Inc. | 12760 Danielson Ct. Unit E, Poway, CA 92064 | www.hitecrcd.com

Содержание RDX2 Mini

Страница 1: ...ION MANUAL WARNING THE CHARGING OF RC HOBBY BATTERIES CAN BE DANGEROUS FAILURE TO FOLLOW THE INSTRUCTIONS AND WARNINGS IN THIS MANUAL MAY RESULT IN PROPERTY DAMAGE AND OR LOSS OF LIFE AC DUAL BALANCE...

Страница 2: ...tery Connections 14 Input Functions 15 Program Flow Chart 17 Charger Operation 18 Memory Set and Call Out 21 BatteryResistanceMeter 23 Warning and Error Messages 24 Advanced System Set Up 25 Commonly...

Страница 3: ...ting instructions included here are designed to ensure that you quickly become familiar with its functions It is important that you read through the Operating Instructions Warning and Safety Notes att...

Страница 4: ...will not be held responsible for any damages or injuries that may occur by persons who fail to follow these warnings or who fail to properly follow the instructions in this manual Warning Be sure to...

Страница 5: ...on flammable and non conductive surface A Never place a charger on a car seat carpet or similar surface Keep all flammable volatile materials away from the operating area A Make sure you know the spec...

Страница 6: ...stated by the manufacturer to be suitable for the currents the charger delivers during the charge process PLEASE BEAR IN MIND THE FOLLOWING POINTS BEFORE YOU COMMENCE CHARGING Did you select the appr...

Страница 7: ...PER BATTERYTYPE AND CELLVOLTAGE FORTHETYPE OF CELLYOU ARE CHARGING CHARGING BATTERIES WITHTHEWRONG SETTINGS MAY CAUSETHE CELLS TO BURST CATCH FIRE OR EXPLODE Charging Before charging your batteries it...

Страница 8: ...red is positive and black is negative Keep in mind that the gauge or thickness of your charging leads from the RDX2 Mini to your battery must be of an acceptable current rating to handle the applied c...

Страница 9: ...t LCD Display LED Indicator Ventilation Fan Alter Values See the Status of Individual Cells in Balance of Charge Mode Switch From Channel A to B or Vice Versa AC Input 100 240V Resume or Start Charge...

Страница 10: ...t Range 0 1 5 0A Balancing Port Current Drain 300mA CELL Trickling Charging Current 50mA 300mA OFF NiCd NiMH Battery Cell Count 6 8 Cells LiPo LiHV LiFe LiIon Cell Count 2 4 Cells Pb Battery Voltage 6...

Страница 11: ...ence Battery Memory Data Store Load The RDX2 Mini is capable of storing up to 10 different charge discharge profiles for your convenience Users can keep the data pertaining to any program setting for...

Страница 12: ...ssary to connect an external balancer for balance charging Adaptable to Various Types of Lithium Battery The RDX2 Mini is adaptable to various types of lithium batteries including LiPo LiIon LiFe and...

Страница 13: ...ce and the internal resistance of each cell Capacity Limit The charging capacity is always calculated as the charging current multiplied by time If the charging capacity exceeds the limit the process...

Страница 14: ...harge leads to the charger first and only then to the battery Reverse the sequence when disconnecting the pack 3 Balance Socket The balance wire attached to the battery must be connected to the charge...

Страница 15: ...sed to enter parameter or store parameter on screen Input Functions BATT Type Stop Button Start Enter Button Stop the progress of the current action or cycle back to the previous step screen Scroll th...

Страница 16: ...rst parameter value When starting the progress press and hold the START ENTER button for 3 seconds When stopping the progress or go back to previous step screen press the BATT PROG STOP button once Wh...

Страница 17: ...RAGE 2 0A 14 4V 4S ENTER START DEC INC DEC INC BATT PROGRAM LiIo BATT LiFe BALANCE 2 0A 13 2V 4S LiFe CHARGE 2 0A 13 2V 4S LiFe STORAGE 2 0A 13 2V 4S ENTER START DEC INC DEC INC DEC INC ENTER START BA...

Страница 18: ...rogram Description This charging mode is for charging LiPo LiHV LiFe LiIon battery in normal mode This program is for charging or discharging lithium battery which will not be used for long time This...

Страница 19: ...C and DEC to change the value and press START ENTER to confirm your setting At the same time the battery cell s number will start to blink Press INC and DEC to change the value and press START ENTER t...

Страница 20: ...to display after the twin channels have been working for 10 seconds And the user is only allowed to be back to the working interface that started lastly with START ENTER and channel switch button Rea...

Страница 21: ...red by pressing START ENTER once Note All following screen are taking 2S 7 4V LiPo battery for example Enter the battery memory program 10 Different charge profiles can be stored START ENTER button Se...

Страница 22: ...s the total resistance Battery Resistance Meter The user can check battery s total resistance Please connect the balance wire attached to the battery to the balance socket and the XT60 male connector...

Страница 23: ...CELL ERROR Incorrect polarity connected The battery is interrupted The battery connection is wrong The balance wires are not connected while charging in balance mode The internal temperature of the u...

Страница 24: ...nd battery cell of the saved profile Indicate the charge current of the saved profile Press the START ENTER for 3 seconds to call out memory START ENTER 3 sconds Battery Memory Call Out Press START EN...

Страница 25: ...o vercharge battery i f it p roves to b e faulty or termination circuit cannot dete battery full The value for the safety should be generous enough to allow charge of the battery OFF ON 100 50000 mAh...

Страница 26: ...sounded at various times during operation to a lert d ifferent m ode changes Load Factory Set ENTE R Versio n HW 1 00 SW 1 10 This program i s for NiMH NiCd battery only When the charger detects the d...

Страница 27: ...d a 3C current value of 3 x 600mA 1800mA or 1 8A The 1C current value for a 3200mAh battery would be 3200mA 3 2A Final Charge Voltage The voltage at which the battery s charge limit capacity limit is...

Страница 28: ...7 4 cell LiHV wired in a series will have a nominal voltage of 14 8 volts 4 x 3 7 Lilo Multiply the total number of cells in the pack by 3 6 A 2 cell Lilo wired in a series will have a nominal voltage...

Страница 29: ...Limits Limits for harmonic current emissions equipment input current up to and including 16 A per phase EN 61000 3 3 2013 Electromagnetic compatibility EMC Part 3 3 Limits Limitation of voltage chang...

Страница 30: ...s charger is designed and approved exclusively for use with the types of batteries stated in this Instruction Manual Hitec RCD USA accepts no liability of any kind if the charger is used for any purpo...

Страница 31: ...iginal purchaser of this product and for products purchased and used in the United States of America Canada and Mexico Plastic cases are not covered by this warranty THIS WARRANTY IS IN LIEU OF ANY AN...

Страница 32: ...ur original receipt showing the purchase date 3 Package your product in its original packaging or use a suspension type packaging foam peanuts or crumpled newspaper Hitec RCD shall not be responsible...

Страница 33: ...33...

Страница 34: ...Hitec RCD USA Inc 12760 Danielson Ct Unit E Poway CA 92064 www hitecrcd com...

Отзывы: