![HITEC RDX1 PRO Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/hitec/rdx1-pro/rdx1-pro_instruction-manual_2139874021.webp)
21
When starting a charge
process, the built-in safety
timer automatically runs at the
same time. This is programmed
to prevent the battery from
overcharging if it proves to be
faulty or if the termination circuit
cannot detect that the battery is
fully charged. The value for the
safety timer should be generous
enough to allow a full charge of
the battery. Default is 120 Min.
Item
Selection
Description
3 - 15mV
Display the temperature in
Celsius or Fahrenheit.
Rest Time allows the battery to
cool down between charging /
discharging cycles.
Delta-peak sensitivity for NiMH/
NiCd battery: The automatic
charge termination program based
on the principle of the Delta-
peak voltage detection. When
the battery’s voltage exceeds the
threshold, the process will be
terminated automatically.
SYSTEM SETUP
Unit:
Resting: 10 Min
Delta Peak: 4mV
Bal. Connection: ON
Celsius
When charging or discharging
batteries, internal chemical
reactions will cause the
temperature of the battery to rise.
If the temperature limit is reached,
the process will be terminated
NOTE: Requires the optional
temperature sensor Part #44159
Description
ON / OFF
Key Beep sounds a beep with
every touch of a button to confi rm
your action. Buzzer plays at various
times during operation to alert the
user to diff erent mode changes.
Both these features can be
turned off .
SYSTEM SETUP
Key Beep:
Buzzer: On
LCD Contrast 100
Factory Reset
On
ON / OFF
Balance Connection can be
switched to OFF to allow you to
charge your battery without the
balance socket connected.
SYSTEM SETUP
Unit:
Resting: 10 Min
Delta Peak: 4mV
Bal. Connection:
ON
Celsius
SYSTEM SETUP
Key Beep:
Buzzer: On
LCD Contrast 100
Factory Reset
On