![HITEC RDX1 PRO Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/hitec/rdx1-pro/rdx1-pro_instruction-manual_2139874016.webp)
16
Operating the Charger (continued)
C. Current (Charge Current)
The charger supports a maximum 10.0A
charge current, but a current suitable for your
battery should be set. It is inappropriate to
set a high charge current for a low capacity
battery, as doing so would result in unwanted
consequences.
*NOTE: This mode is only available under the
Charge mode
D. Current (Discharge Current)
The charger supports a maximum -2.0A
discharge current, but users should set the
appropriate discharge current for the battery in
use.
* Note that this mode is only available under the
Discharge mode.
Target Volt - (Target Voltage)
This function is available when working with
Lithium and Lead Acid (Pb) chemistry batteries.
Here you can set the target voltage for each
individual cell.
WARNING: Setting the target voltage too
high can damage your battery and cause
your battery to explode. See the packs
manufacturer’s recommended settings before
changing this value from the defaults.
Cut Volt - (Cutt-off Voltage)
This function can be activated under Discharge
mode no matter the type of batteries being
discharged. This function protects a battery
from deep discharging. Refer to the chart on
page 6 for recommended cut-off voltage.
PROGRAM SELECT(01)
C. Current 3.3A
D. Current OFF
Target Volt: 4.20V
Cut Volt: OFF
PROGRAM SELECT(01)
Battery Type: LiPo
Battery Cells: 3S
Mode: Balance
C. Current 3.3A
PROGRAM SELECT(01)
Mode: Discharge
C.Current OFF
D. Current -2.0A
Battery Cells: 3S
PROGRAM SELECT(01)
C. Current 3.3A
D. Current OFF
Target Volt: 4.20V
Cut Volt: OFF