HITEC Multi-Charger X2-400 Скачать руководство пользователя страница 6

04

Optimized Operating Software

The software in X2-400 automatically controls the current rate during the charging or 
discharging process. This feature can prevent the user from overcharging their batteries 
which could lead to damage or injury. If the charger detects a malfunction, the circuit 
automatically disconnects and an alarm will sound, The operating functions of the 
X2-400 are controlled through a two-way communication link in order to maintain 
maximum safety with minimal errors. All of these functions and settings are easily config-
ured by the user.

Internal Independent Lithium Battery Balancers

Each channel of the X2-400 employs an individual-cell voltage balancer eliminating the 
need for an external balancer for balance charging.

Monitors Individual Cells During Battery Discharging

During the process of discharging, the X2-400 can monitor and display each cell of 
lithium type batteries individually. If the voltage of any single cell is abnormal, an error 
message will display and the discharge process will automatically end.

Charges Most Popular Lithium Batteries

The X2-400 is compatible with the three most common Lithium chemistry batteries, 
Li-Ion, LiPo and LiFe.

Multiple Lithium Battery Charge Modes

The X2-400’s programming allows for Fast Charge, Balance Charge or Storage Charge 
Modes for LiPo, Li-Ion, and LiFe batteries.

‡)DVW&KDUJH0RGH

 Reduces charging time, but does not balance the cells, this 

  mode only charges the battery to approximately 90% capacity. 

‡%DODQFH&KDUJH0RGH

 Monitors individual cell voltage, keeping the cells within an 

  acceptable voltage range and charges the pack to peak capacity. 

‡6WRUDJH&KDUJH0RGH

 Used for long-term battery storage. Adjusts the voltage 

   level so the battery will not be damaged during long term storage.

Delta Peak Technology for Maximum Safety

The automatic charge termination program utilizes Delta-Peak voltage detection.   
When the battery's voltage exceeds the threshold, the charge process is terminated 
automatically.

Automatic Charging Current Limit

The maximum charge rate can be manually set when charging NiCd or NiMH batteries. 
The X2-400 will auto-detect when the batteries are fully charged and shut off, even with 
low impedance NiMH packs.

SPECIAL FEATURES

Содержание Multi-Charger X2-400

Страница 1: ......

Страница 2: ...mation 13 Charging Lithium Chemistry LiPo LiIo LiFe Type Batteries 13 Discharging Lithium Chemistry LiPo LiIo LiFe Type Batteries 16 Charging Discharging and Cycling NiCd or NiMH Batteries 17 Charging...

Страница 3: ...the include connector you connect it to a 12 18 V DC power supply with a minimum amperage rating of 60 amps The Hitec X2 400 is simple to use but the operation of a sophisticated automatic charger suc...

Страница 4: ...Fe battery into any of the charging ports This eliminates the time consuming efforts of charging all your batteries separately Discharger Power 25 Watts per Channel Power Source Charge Power Cell Coun...

Страница 5: ...u Control Buttons Temp Sensor PC Link Temp Sensor PC Link Universal Balancing Port Universal Balancing Port Battery Socket Battery Socket Input DC 12 18 Ventilation Fan With Temperature Sensor Ventila...

Страница 6: ...e process will automatically end Charges Most Popular Lithium Batteries The X2 400 is compatible with the three most common Lithium chemistry batteries Li Ion LiPo and LiFe Multiple Lithium Battery Ch...

Страница 7: ...ot included in our package 5 User Customizable Presets per Port Each port of the X2 400 features 5 individually customizable presets so the user can store the charge and discharge parameters for any p...

Страница 8: ...RGXFW DV LW FRYHUV D ZLGH UDQJH RI LQIRUPDWLRQ RQ RSHUDWLRQ DQG VDIHW NEVER OHDYH WKH FKDUJHU XQDWWHQGHG ZKHQ LW LV FRQQHFWHG WR LWV SRZHU VXSSO I DQ PDOIXQFWLRQ LV IRXQG 7 50 1 7 7 352 66 7 21 DQG UH...

Страница 9: ...QO EDWWHULHV WKDW DUH H SUHVVO VWDWHG WR EH FDSDEOH RI TXLFN FKDUJH VKRXOG EH FKDUJHG DW UDWHV KLJKHU WKDQ WKH VWDQGDUG FKDUJH FXUUHQW RQQHFW WKH EDWWHU WR WKH WHUPLQDO RI WKH FKDUJHU 5HG LV SRVLWLYH...

Страница 10: ...age setting as well as the individual cell voltage 4mm bullet connectors plug directly into most power supplies Using terminal clip attaching to car battery POWERING THE CHARGER WARNINGS AND SAFETY IN...

Страница 11: ...ries supported by the X2 400 LiFe 3 3V Lilo 3 6V or LiPo 3 7V If you plan to use one type of Lithium chemistry battery you can set the default here WARNING Make sure when you connect your battery that...

Страница 12: ...ting then press INC to move on to the next parameter Waste Time Setting When charge discharge cycling a battery the battery will become warm You can set a time delay ranging from 0 to 60 minutes after...

Страница 13: ...will end forcibly to protect the input source Once you have established the desired settings press Start Enter to confirm the setting You have now set the initial user settings You can repeat this pro...

Страница 14: ...12 PROGRAM FLOW CHART...

Страница 15: ...ws the present input voltage going to the charger When the battery is connected to the balancing port you can check the voltage of each cell in the battery pack The program can display the voltages of...

Страница 16: ...nge the settings press the START ENTER key to make it blink then use the DEC or INC key to change the setting Then press the START ENTER key again to store the setting A Lithium battery is charged at...

Страница 17: ...number of cells the processor detects as S If both numbers are identical you can start charging by pressing the START ENTER button If not press the BATT TYPE STOP button to go back to the previous sc...

Страница 18: ...l state of the battery exceeds the voltage level for storage WARNING Lithium batteries cannot be discharged to a voltage lower than the minimum voltage for the cell type Doing so will result in a rapi...

Страница 19: ...een Auto and Manual Mode using the charge current you set up In the auto mode you should set the upper limit of the charge current to avoid damage caused by excessive charge current This is especially...

Страница 20: ...of the battery being charged or discharged Use the INC or DEC keys to scroll through the results of each cycle This program is only suitable for charging a lead acid PB type battery with a nominal vo...

Страница 21: ...the Default User Preferences Setup section of this manual to set up this feature Charging Lead Acid Pb Batteries Set up the discharge current on the left and the nominal voltage on the right The disch...

Страница 22: ...and a capacity of 3000mAh When you have completed this process press and hold the START ENTER key for 3 seconds to enter the charge discharge setup screen Set up the charge current in the manual mode...

Страница 23: ...c RCD USA customer service department immediately The voltage is lower than which is set check the number of cells in the battery pack The voltage is higher than which is set check the number of cells...

Страница 24: ...18 0 16 0 7 4 9 8 12 3 14 8 17 2 19 7 22 1 24 6 6 0 8 0 10 0 12 0 14 0 16 0 18 0 20 0 3 4 2 5 2 0 1 7 1 5 1 3 1 1 1 0 Pb Battery Type 5 0 3 0 2 0 1 5 1 2 1 0 5 0 3 0 2 0 1 5 1 2 1 0 5 0 3 5 2 3 1 7 1...

Страница 25: ...ins chemicals known to the State of California to cause cancer Use caution when handling this product and avoid exposure to any electronic components or internal assemblies RECOMMENDED ACCESSORIES EN...

Страница 26: ...PLIED WARRANTY RELATING TO THIS PROD UCT EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW ANY IMPLIED WARRANTY OF MERCHANABILITY OR FITNESS FOR A PARTICUALR PURPOSE ON THIS PRODUCT IS LIMITED IN DURA...

Страница 27: ...1 Presets Preset No Battery Type Charge Mode Charge Discharge Current Charge Discharge Voltage 1 2 3 4 5 Preset No Battery Type Charge Mode Charge Discharge Current Charge Discharge Voltage 1 2 3 4 5...

Страница 28: ...All specifications and figures are subject to change without notice...

Отзывы: