Fail safe and hold mode
When Rx signal take effect on external influence if you set the Fail - safe mode, the servo will go to Fail–safe position you stored already. The servo
will turn off the power for 1 second in hold time if you didn’t enable the Fail–safe mode. Then the servo will keep no-load condition and move to the
position that is ordered last time until it detects a normal signal again. Always, the Fail-safe mode must be enable for safe flight and the Fail-safe
mode is required safe flight status like the engine idling, the motor stop, extended air brake, etc.
-
Fail-safe set-up
1.
After the transmitter power ON SET 1/2 TAB to select the FAILSAFE.
2.
If you select SET on each channel can be set as the FAILSAFE mode.
3.
ST & TH moves and the number at the bottom of the current value is displayed.
4.
After setting the desired value, press SET to save the value.
5.
May set the value stored for each channel by pressing the SEND Data is sent to the receiver.
6.
Once the receiver is receiving Data ON after the power is turned OFF.
7.
Check the servo move to the Fail-safe position.
-
Fail-safe Setting TEST
1.
The flight move to the any place that is not the Fail-safe setting.
2.
It is the normal Fail-safe setting if the servo moves to the Fail-safe position you set lastly after you turn off the Tx.
-
The way to re-enable the Hold mode in Fail-safe mode.
1.
After the transmitter power ON SET 1/2 TAB to select the FAILSAFE.
2.
Each channel is HOLD selected, HOLD mode can be set.
3.
ST & TH moves and the number at the bottom of the current value is displayed.
4.
After setting the desired value, press SET to save the value.
5.
May set the value stored for each channel by pressing the SEND Data is sent to the receiver.
6.
Once the receiver is receiving Data ON after the power is turned OFF.
7.
Check the servo move to the Fail-safe position.