HITEC HFP-30 Скачать руководство пользователя страница 6

2. Servo Sync 

To match two servos together, use the Servo Sync option when 

programming Neutral and Endpoints. The first step is to program and 

save the first servo at the desired positions. Exit the programming 

mode and then place the programmed servo into the SYNC slot of 

the HFP-30. Place the next servo into the Servo slot and enter the 

programming mode. Enter the EPA and Neutral Setting menu and 

begin programming the servo. As the servo’s neutral and endpoints 

are adjusted, you will see the servo in the SYNC slot move to its 

preprogrammed center and endpoints allowing easy matching of the 

new servo and those positions.

3. Rotation (CW_CCW):

Highlight CW_CCW on the main screen and press the Adjust Dial to 

enter the menu. Under the Now Values will be the current rotation 

direction. Below will be the value to set. Use the Adjust Dial to change 

from CW to CCW. Once at the desired rotation, press the Adjust Dial to 

save the value to the Now Values. Press the BACK button to exit to the 

main menu.

4. Deadband (DB_Width):

Highlight DB_Width on the main screen and press the Adjust Dial to 

enter the menu.

Note: Hitec Digital Servos from the factory are set to the tightest 

Deadband possible by default. Even if the Deadband can be set 

lower with the programmer, it will have no effect on the servo.

Once in the menu, the current Deadband is displayed under Now 

Values. Use the Adjust Dial to change the value under the Set Values. 

Once the desired Deadband is reached, press the Adjust Dial to save 

the value to Now Values. Use the BACK button to exit to the main 

menu. Values for the Deadband are 1-20.

5. Speed:

Highlight Speed in the main menu and press the Adjust Dial. Once 

in the menu, the current speed is displayed under Now Values. Use 

the Adjust Dial to change the value under the Set Values. Once the 

desired speed is reached, press the Adjust Dial to save the value to 

Now Values. Use the BACK button to exit to the main menu. Values for 

speed are 10 – 100%.

6. Failsafe:

Sometimes it is desired to have the servo go to a preset position when 

it loses signal. 

To enter the menu, use the Adjust Dial to scroll to page 2 of the main 

menu and press the dial once highlighted. Follow the on-screen 

instructions and center the Pulse Dial. Current Failsafe settings are 

listed under ‘Now Values’. Use the Pulse Dial to set the Failsafe 

position. Once set, use the Adjust Dial to turn Failsafe on or off. 

Press the Adjust Dial to save setting to servo. The new setting will be 

displayed in the ‘Now Values’.  Use the Back button to exit the menu.

7. Soft Start:

The Soft Start feature, depending on the setting, allows the servo to 

either quickly or slowly move to the received signal when first turned 

on. Once it reaches the correct position, normal operation of the servo 

resumes. By default, this feature is enabled on D Series servos. To 

enter the menu, use the Adjust Dial to scroll to page 2 of the main 

menu and press the dial once highlighted. Current Soft Start settings 

are listed under ‘Now Values’. To change the values, turn the Adjust 

Dial to the desired percentage and press the dial to set it. The new 

setting will be displayed in the ‘Now Values’. Use the Back button to 

exit the menu.

8. Factory Default (Factory Default Set):

Sometimes it is best to restore the servo back to Factory Default 

settings. To enter the menu, use the Adjust Dial to scroll to page 2 of 

the main menu and press the dial once highlighted. Follow the on-

screen prompts to reset the servo. Once each prompt is completed, 

the corresponding box will say OK. After the last one, the servo will be 

reset to factory defaults.

NOTES:

Hitec RCD USA, Inc. | 12115 Paine St., Poway CA, 92064

www.hitecrcd.com | 858.748.6948 | [email protected]