The Settings menu is where specific test parameters can be set for 

all servo test modes. Use the Adjust Dial to highlight SETTING and 

press it to enter the menu.

To make adjustments to the various settings, use the Adjust Dial to 

highlight it and then press the dial to enter editing mode. To change 

the value, use the Adjust Dial. Either press it again to confirm and 

exit or press the BACK button to exit without saving.

The different features that can be edited are:

GYRO MODE (ON/OFF): This is for use with specifically designed 

tail rotor servos. These servos generally use a different neutral and 

endpoints than other servos. Turning this feature on will automatically 

reset the pulse widths and frame rate for testing. Do not use this 

setting unless the servo being tested states it is a high frame rate tail 

rotor servo.

PULSE_w (Pulse Range): For setting the Pulse Width Test 

parameters for a servo. The adjustments are made to middle 

(neutral), minimum and maximum endpoints. To edit a point, highlight 

it using the Adjust Dial and then press the dial to begin editing. 

The range for each is:

Mid: 1100 – 1900 microseconds

Min: 100 – 1500 microseconds

Max: 1500 – 2520 microseconds

Note: Adjust these settings with caution. If the pulse is too wide, 

the servo may stall which will cause damage.

PULSE_p (Frame Rate): The Frame Rate is how fast the signal 

is sent to the servo. The lower the number the faster the signal is 

sent. The range is from 3 milliseconds to 30 milliseconds. Caution is 

required as analog servos cannot handle frame rates faster than 14 

milliseconds. Doing so will cause damage.

 

STEP VALUES: The increments moved when testing. The range is 

from 0.25 microseconds 

to 1 microsecond.

TEST: The speed and number of cycles to test at when using AUTO 

E/S/S mode. 

The ranges are:

Speed: 0.1 second to 5.0 seconds.

Count: 0 - 50000 cycles.

LCD Contrast: Change the LCD screen contrast for better 

personalized viewing.

SET Default: Revert all settings to their defaults.

To program the different series of Hitec digital servos, plug the servo 

into the SERVO port of the programmer and the battery or receiver 

into the BATT/RX port. Once connected, move the selector switch 

to the PROG position. On the SERIES SELECTION screen, use the 

Adjust Dial to select the appropriate series of the servo connected. 

Press the dial to enter the menu. Each setting is selected with the 

Adjust Dial. Once highlighted, press the dial to edit.

Note: It is highly recommended that the servo being programmed 

is not connected to any linkage.

1. EPA Neutral Settings

Press the Adjust Dial to enter the menu. If the Pulse Dial is off center, 

the program will ask that the dial is center so the indicator is at 12 

o’clock. Once adjusted, the Neutral Settings screen will appear. Use 

the Adjust Dial to elect either to change the Neutral position or to 

skip and move on to the endpoints. 

To change the Neutral position, highlight NEUTRAL, and press the 

Adjust Dial to enter the edit mode.  To make an adjustment, use the 

Pulse Dial. To save the setting to the servo, press the Adjust Dial, 

otherwise, press the BACK button to exit without making a change.

Note: Changing the neutral position to an extreme will affect the 

throw of the servo’s endpoints. Try to never vary the position too 

far from nominal. Also, if the neutral position is programmed, then 

the endpoints must be programmed. 

The endpoints can be programmed without setting the neutral 

position. To do this, highlight ‘Skip to Neutral Set’ and press the 

Adjust Dial.

To set the Left or Right position of the throw, highlight the direction 

and press the Adjust Dial to edit. Once in editing, use the Pulse Dial 

to make changes. Press the Adjust Dial to confirm or the BACK 

button to exit without saving. 

After making changes to the servo’s EPA settings, use the BACK 

button to return to the main screen. This will save the settings to the 

servo. Once back at the main screen, the recently saved changes will 

show below the EPA Neutral Settings.

Note: The Hitec Digital Servos are programmed to match a .9 to 

2.1 millisecond pulse width with 1.5 millisecond pulse as neutral. 

When plugged into a receiver, the programmed positions might 

vary slightly due to manufacturing differences from radio to radio. 

EPA percentages and subtrim might have to be used for final 

adjustment.

2. Servo Sync 

To match two brushless servos together, use the Servo Sync option 

when programming endpoints. The first step is to program and 

save the first servo at the desired positions. Exit the programming 

mode and then place the programmed servo into the SYNC slot of 

the HFP-30. Place the next servo into the servo slot and enter the 

programming mode. Enter the EPA and Neutral Setting menu and 

begin programming the servo. As the servo’s endpoints are adjusted, 

you will see the servo in the SYNC slot move to its preprogrammed 

endpoints allowing easy matching of the new servo and those 

positions.

3. Rotation (CW_CCW)

Highlight CW_CCW on the main screen and press the Adjust Dial to 

enter the menu. Under the Now Values will be the current rotation 

direction. Below will be the value to set. Use the Adjust Dial to 

change from CW to CCW. Once at the desired rotation, press the 

Adjust Dial to save the value to the Now Values. Press the BACK 

button to exit to the main menu.

Settings

D Series Program Mode

Programming