HITEC
ALP842-Datasheet-R1
5 / 11
HITEC – 61, rue Jean Jaurès – 91160 CHAMPLAN – Tel. : 01 69 74 10 90 – Fax : 01 69 74 10 99
charge 1
Neutre
NO1 (12)
NO2 (11)
NO3 (14)
NO4 (15)
Phase
COM (16)
charge 2
charge 3
charge 4
ALP842
∆
Wiring 4 charges (230Vac, 5A max) on the 4 relays
8. Wiring connections
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
N
L
NO1 NO2 NO3 NO4 COM GND +24V
230VAC
Sensor power
supply
4 relay outputs
mA+
V+ mV+
V-
mA-
+
-
Analog output
PT100
Rear view (terminals)
+
-
Numéro
Description
L et N
Phase and neutral (Power supply 230Vac)
2
+ Input signal current (mA)
3
+ Input signal voltage (V)
4
+ Input signal voltage (mV)
5
- Input signal current or voltage
8
+ Analog output
9
- Analog output
12
Relay 1 : Point normally open (NO)
13
Relay 2 : Point normally open (NO)
14
Relay 3 : Point normally open (NO)
15
Relay 4 : Point normally open (NO)
16
Relay common (COM)
17
Ground 24VDC power supply for the sensor (GND)
18
+ 24VDC power supply for the sensor (+24V)