The following table shows the available analog input settings. Parameter A005 and the
input terminal [AT] determine the External Frequency Command input terminals that
are available, and how they function. The analog inputs [O] and [OI] use terminal [L] as
the reference (signal return).
A005
[AT] Input
Analog Input Configuration
ON
Keypad Pot
02
OFF
[O]
ON
Keypad Pot
03
OFF
[OI]
04
(ignored)
[O]
05
(ignored)
[OI]
NOTE: You cannot use [O] and [OI] inputs simultaneously on the X200 series inverter.
Other Analog Input-related topics:
x
“Analog Input Settings” on page 3–13
x
“Additional Analog Input Settings” on page 3–28
x
“Analog Signal Calibration Settings” on page 3–61
x
“Analog Input Current/Voltage Select” on page 4–22
x
“ADD Frequency Enable” on page 4–30
x
“Analog Input Disconnect Detect” on page 4–46
4
56
Inverter Mounting
and i
n
st
all
ation
4
−
56
Operations and
Monitoring
Содержание X200 Series
Страница 21: ......
Страница 83: ......
Страница 149: ......
Страница 184: ... this page is left intentionally blank 4 35 Operations and Monitoring 4 35 Operations and Monitoring ...
Страница 211: ......
Страница 219: ......
Страница 236: ...Glossary and Bibliography In This Appendix page Glossary 2 Bibliography 8 A A 1 Appendix A A 1 Appendix A ...
Страница 283: ......
Страница 293: ......
Страница 299: ......