I
i
SJ700 series Inverter parameter setting for solar water pump inverter
After giving power to inverter, It show 0000 value of d001 parameter (output motor
Hz)
Check A017 = 01 For enabling MPPT algorithm, 00 means stop, 01 means for
terminal enabling.
And Check Short link between terminal P24 and FW where Short link seen between
PLC and CM1 terminal.
First to set motor data inside of inverter like KW, Hz, RPM, Current, Votlage
A003 = Hz of motor
H003 = KW of motor
H004 = Pole of motor which come from RPM of motor.
A002 = 01 Terminal Run command
F002 = 100
Sec , Acceleration Time
F003 =
1
Sec , Deceleration time
A020 = Put Total Vmp of connect PV cells,
C001 = 56, Terminal 1 as Forward Run command
C006 = 18, Terminal 6 as Reset inverter
P101 = 3 min,
Auto restart delay time after inverter get any alarm, Change as per requirements
P1
30
= 3000,
Water level sensitivity,
For 60Hz Pump Make :
1- A017 = 00
2- Remove FW
3- P111 = 6000
Note : Make B037 = 00
4- A061 = 60
5- A003 = 60
6- A017 = 0
1
7- FW Back