3 - 11
PC Display & Figs
Procedure:
1)
Input E to PC on the main menu screen.
2)
Follow the instructions on PC display thereafter.
3)
The screen for verifying writing of spot noise data will appear: Input Y. (*1)
4)
When writing data is complete, the spot noise data write complete screen will appear: Press any key to restore the
main menu screen.
*1:
Entering N on the screen for verifying writing of spot noise data will restore the main menu screen.
5.6
IR Control
(1) IR Control Adjustment
Condition:
Cap the lens (so that no light enters).
Procedure:
1)
Input F to PC on the main menu screen.
2)
Follow the instructions on PC display thereafter.
3)
After the IR control adjustment complete screen appears, press any key to restore the adjustment menu screen.
Main menu
***********************************************************
MANUAL ADJUSTMENT PROGRAM
***********************************************************
[A]
DATA INITIALIZE
[B]
ELECTRIC VOLUME
[C]
ADJUSTMENT
[D]
AUTO FOCUS
[E]
SPOT NOISE
[F]
IR CONTROL
[ESC] END
Please select [A] - [F] or [ESC]
FINISHED WRITING DATA
PRESS ANY KEY
<< DATA WRITING >>
START TO SEND DATA. (Y/N)
Screen for verifying writing of spot noise data
FINISHED WRITING DATA
PRESS ANY KEY
Spot noise data write complete
IR control adjustment complete