List of Adjustment Items
The following table shows the adjustment items, their purposes, and whether or not check is required after replacing major
components.
The components shown in the table below are the minimum to be checked after replacing major components: If several
components have been replaced - or depending on the cause of a defect - more components may need to be checked.
: CHECK
*1: When replacing the PC circuit board (containing EEPROM) or EEPROM, be sure to perform all adjustments
only after “Data Initialize”.
*2: Since all adjustments must be performed any time “Data Initialize” is done, do not perform it indiscriminately.
Item of Adjustment
Data Initialize
(1) Data Initialize (*2)
Electric Volume
(1) CDS Sampling
Pulse
Adjustment
(1) Auto Iris Control
(2) White Balance
(3) Chroma Gain
Autofocus
(1) Zoom/Focus
Tracking
(2) AF Noise Level
(3) Check of Zoom
Trace
Spot Noise
(1) Spot Noise
IR Control
(1) IR Control
Purpose of Adjustment
Initilizing EEPROM.
To suppress noise in the CCD sensor
output signal and maximize the signal
level.
To set the iris control data.
To input the automatic wihite balance
control data.
To set the color saturation under the
reference color temperature.
To set the out-of -focus correction level
during zooming.
To set the noise level in the autofocus
circuit.
To check the autofocus adjustment.
To correct spot noise.
To set the IR filter control data.
SP circuit
board
IC1001
IC1201
IC1250 (*1)
IC1351
Name of Major Components
IC1101
PC circuit
board (*1)
Lens Block