4.
To turn on the storage system, click
Power Management > Power on
Storage System
. At the confirmation message, click
Submit
.
5.
To turn off the storage system, click
Power Management > Power off
Storage System
. At the confirmation message, click
Submit
.
Using LEDs to diagnose problems
The storage system LEDs provide system status and diagnostic indicators.
If the storage system used in a remote TrueCopy configuration restarts with
the TrueCopy status of
enabled
, the following occur:
• The path used by TrueCopy becomes blocked. Notifications from the
Hitachi Device Manager - Storage Navigator email alert function, SNMP
Agent Support function, and SNMP trap occur when the path is blocked.
Follow the instructions in the notification. The blocked path recovers
automatically after restarting the storage system.
• If the TrueCopy pair status is
PAIR
or
COPY
, the pair changes to
PSUE
. In
this case, suspend the pairs before restarting the storage system.
Power LED does not go on
Procedure
1.
Set the main switch to on.
2.
Is the Power LED on at the controller?
• Yes: Go to step 9.
• No: Power on the host computer.
3.
Is the Power LED on at the controller?
• Yes: Go to step 9.
• No: Set the main switch to off.
4.
Check that the PDU on the rack is delivering power to the storage
system.
5.
Verify that the AC cable is correctly connected to the plug socket and the
equipment.
6.
Set the main switch to on.
7.
Is the Power LED on at the controller?
• Yes: Go to step 9.
• No: Set the main switch to off.
8.
Contact your administrator. Go to step 10.
9.
Is the Ready LED on?
• Yes: Continue to use the equipment, even if the green Ready LED
blinks fast.
• No: Use the following corrective action. See
or Ready LED went on and then off on page 390
.
Troubleshooting the storage system
389
Service Guide for VSP Gx00 and VSP Fx00 Models
Содержание Virtual Storage Platform F400
Страница 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 222: ...222 Replacing a small form factor pluggable SFP Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 395: ...CBSS CBSSD controller Warning labels on the storage system 395 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 396: ...CBSL CBSLD controller 396 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 398: ...CBLM controller CBLH controller 398 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 401: ...Flash module drive tray Warning labels on the storage system 401 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 402: ...Dense intermix drive tray 402 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 410: ...PCIe switch board 410 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 411: ...NAS module Warning labels on the storage system 411 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...