Miscellaneous Hitachi Device Manager - Storage Navigator
troubleshooting
Failure
Recovery Action
After registering the storage system
successfully, any error occurred during
operation.
Check the status of the Device Manager - Storage
Navigator background services and take appropriate action
(see
Background service log on page 344
).
).
If the collection fails, collect the target files manually (see
Collecting dump files manually on page 380
).
After changing the registered user
account without stopping the services
of the registered storage system, the
"20122-208003" error occurred during
the Hitachi Device Manager - Storage
Navigator operations.
Stop the service of the registered storage system in the
Storage Device List
. Click Edit to register the enabled
user account information again, and then start the service.
Troubleshooting NAS Manager
If you experience problems using NAS Manager, refer to the troubleshooting
procedures in the following sections.
Setting disk capacity assignments
Failure
Recovery
The LDEV created by Device Manager - Storage
Navigator or Hitachi Command Suite is not
reflected.
Refresh NAS Manager.
The system drive to create a storage pool is not
shown in the window.
To create a storage pool, four or more LDEVs are
required. Start Device Manager - Storage
Navigator or Hitachi Command Suite to create
LDEVs. NAS might not be selected when adding
the LUN path to LDEVs. For more information
about creating LDEVs, see the Hitachi Virtual
Storage Platform Installation and Reference
Guide for your storage system model.
Start Device Manager - Storage Navigator and
set the LUN path of the LDEVs to be assigned to
the storage pool for the NAS platform (user LU).
For more information about allocating LDEVs to
LUN paths, see the Hitachi Virtual Storage
Platform Installation and Reference Guide for
your storage system model.
EVS cannot be created.
The common subnet mask must be assigned to
EVS in which the same link aggregation is set.
Specify the same numerical value as the subnet
Troubleshooting the storage system
335
Service Guide for VSP Gx00 and VSP Fx00 Models
Содержание Virtual Storage Platform F400
Страница 4: ...4 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 22: ...22 Preface Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 106: ...106 Replacing storage system components Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 140: ...140 Replacing a fan Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 146: ... CBLM CBLH 146 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 160: ...160 Replacing a power supply Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 198: ...6 Click Block 198 Replacing cache memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 222: ...222 Replacing a small form factor pluggable SFP Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 250: ...250 Replacing a SAS cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 260: ...260 Replacing cache flash memory Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 268: ...268 Replacing a LAN blade Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 278: ...278 Replacing a backup module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 284: ...284 Replacing a PCIe module Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 296: ...296 Replacing a PCIe cable connector Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 302: ...302 Replacing a PCIe cable Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 312: ...312 General maintenance Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 395: ...CBSS CBSSD controller Warning labels on the storage system 395 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 396: ...CBSL CBSLD controller 396 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 397: ...Warning labels on the storage system 397 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 398: ...CBLM controller CBLH controller 398 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 401: ...Flash module drive tray Warning labels on the storage system 401 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 402: ...Dense intermix drive tray 402 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 405: ...Warning labels on the storage system 405 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 410: ...PCIe switch board 410 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 411: ...NAS module Warning labels on the storage system 411 Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 412: ...412 Warning labels on the storage system Service Guide for VSP Gx00 and VSP Fx00 Models ...
Страница 417: ...Service Guide for VSP Gx00 and VSP Fx00 Models ...