– 108 –
LD301 b
links 6 time
.
The temper
ature at the
OH thermistor rises.
LD301 b
links 5 time
.
Ov
erload lo
w
er limit cut.
LD301 b
links 4 time
.
F
ailure of s
witching.
LD301 b
links 3 time
.
Abnor
mal lo
w speed.
Replace parts in the
thermistor circuit.
No
No
No
Chec
k contin
uity of ne
w par
ts.
Chec
k continuity of patter
n and
lead wires according to the
P
.W
.B
. and schematic diag
rams
.
Ye
s
Ye
s
Replace system power
module or defective parts.
Replace the system power
module.
Replace any defective
parts.
Is the thermistor circuit normal?
Are R503 and per
ipher
al
circuits of system po
w
er module
nor
mal?
Replace the main P
.W
.B
.
Is the system power module
normal?
Is the drive circuit normal?