– 107 –
Ye
s
N
o
No
Ye
s
Ye
s
Ye
s
No
No
No
LD301 b
links 8 time
.
Acceler
ation def
ect.
LD301 b
links 7 time
.
Ther
mistor abnor
mal.
Is the power module normal?
Is the drive circuit normal?
Is the thermistor connector
disconnected?
❈
The problem may be
“forgetting
to connect after servicing
”.
Is the continuity of thermistor normal?
Is the thermistor circuit normal?
Replace the po
w
er module.
Replace any def
ectiv
e par
ts
.
Connect the ther
mistor
.
Replace the ther
mistor
.
Replace par
ts in the
thermistor circuit.
Chec
k continuity of patter
n and
lead wires according to the
P
.W
.B
. and schematic diag
rams
.
Chec
k continuity of patter
n and
lead wires according to the
P
.W
.B
. and schematic diag
rams
.