APPENDIX PARAMETER CROSS-REFERENCE LIST
22
Parameter cross-reference list
To be able to read/write parameters via Profibus it is necessary to use a cross-reference list to convert from
Profibus parameters to actual parameter values in the inverter.
Example, if parameter “1st Acceleration time 1” shall be read then parameter number 23 shall be used (if the
keypad is used F002 is used).
The L300P inverter supports a slightly different parameter map; the “L300P” field reflects this. “No” means
that the L300P inverter does not support the parameter, a figure means that the parameter is supported, but
with this maximum value instead.
Code No. Size
Range
Magn.
Contents
L300P
Read/
Write
A020
1
4
0
〜
400.00Hz
*100
1st setting Multispeed frequency 0
R/W
A220
2
4
0
〜
400.00Hz
*100
2nd setting Multispeed frequency 0
R/W
A320
3
4
0
〜
400.00Hz
*100
3rd setting Multispeed frequency 0
No
R/W
A021
4
4
0
〜
400.00Hz
*100
Multispeed frequency 1
R/W
A022
5
4
0
〜
400.00Hz
*100
Multispeed frequency 2
R/W
A023
6
4
0
〜
400.00Hz
*100
Multispeed frequency 3
R/W
A024
7
4
0
〜
400.00Hz
*100
Multispeed frequency 4
R/W
A025
8
4
0
〜
400.00Hz
*100
Multispeed frequency 5
R/W
A026
9
4
0
〜
400.00Hz
*100
Multispeed frequency 6
R/W
A027
10
4
0
〜
400.00Hz
*100
Multispeed frequency 7
R/W
A028
11
4
0
〜
400.00Hz
*100
Multispeed frequency 8
R/W
A029
12
4
0
〜
400.00Hz
*100
Multispeed frequency 9
R/W
A030
13
4
0
〜
400.00Hz
*100
Multispeed frequency 10
R/W
A031
14
4
0
〜
400.00Hz
*100
Multispeed frequency 11
R/W
A032
15
4
0
〜
400.00Hz
*100
Multispeed frequency 12
R/W
A033
16
4
0
〜
400.00Hz
*100
Multispeed frequency 13
R/W
A034
17
4
0
〜
400.00Hz
*100
Multispeed frequency 14
R/W
A035
18
4
0
〜
400.00Hz
*100
Multispeed frequency 15
R/W
A061
19
4
0
〜
400.00Hz
*100
1st Upper limiter frequency
R/WOS
A261
20
4
0
〜
400.00Hz
*100
2nd Upper limiter frequency
R/WOS
A062
21
4
0
〜
400.00Hz
*100
1st Lower limiter frequency
R/WOS
A262
22
4
0
〜
400.00Hz
*100
2nd Lower limiter frequency
R/WOS
F002
23
4
0.01
〜
3600.00s
*100
1st Acceleration time 1
R/W
F202
24
4
0.01
〜
3600.00s
*100
2nd Acceleration time 1
R/W
F302
25
4
0.01
〜
3600.00s
*100
3rd Acceleration time 1
No
R/W
F003
26
4
0.01
〜
3600.00s
*100
1st Deceleration time 1
R/W
F203
27
4
0.01
〜
3600.00s
*100
2nd Deceleration time 1
R/W
F303
28
4
0.01
〜
3600.00s
*100
3rd Deceleration time 1
No
R/W
A092
30
4
0.01
〜
3600.00s
*100
1st Acceleration time 2
R/W
A292
31
4
0.01
〜
3600.00s
*100
2nd Acceleration time 2
R/W
A392
32
4
0.01
〜
3600.00s
*100
3rd Acceleration time 2
No
R/W
A093
33
4
0.01
〜
3600.00s
*100
1st Deceleration time 2
R/W
A293
34
4
0.01
〜
3600.00s
*100
2nd Deceleration time 2
R/W
A393
35
4
0.01
〜
3600.00s
*100
3rd Deceleration time 2
No
R/WOS