APPENDIX PARAMETER OBJECT LISTS
28
Address
Size
Setting
range
magn.
Contents
L300P
operator
code
H'0800027A
1 00
〜
03
code
Selection of method of overload restriction2
b024
H'0800027B
1 00
〜
03,10
code
Selection of method of Software lock
b031
H'0800027C
1 00
〜
02
code
Selection of Display
b037
H'0800027D
3 -
-
Access Inhibited
No
-
H'08000280
1 00
〜
04
code
Selection of method of Torque limiter
No
b040
H'08000281
1 0
〜
200%
*1
Level of torque limiter in forward and drive
(1st quadrant)
No
b041
H'08000282
1 0
〜
200%
*1
Level of torque limiter in reverse and regenerative
(2nd quadrant)
No
b042
H'08000283
1 0
〜
200%
*1
Level of torque limiter in reverse and drive
(3rd quadrant)
No
b043
H'08000284
1 0
〜
200%
*1
Level of torque limiter in forward and regenerative
(4th quadrant)
No
b044
H'08000285
1 00,01
code
Selection of LAD stop by torque
No
b045
H'08000286
1 00
〜
02
code
Selection of running direction limitation
b035
H'08000287
1 00,01
code
Selection of preventive of reverse running
No
b046
H'08000288
1 00
〜
06
*1
Selection of method of reducing voltage start
b036
H'08000289
1 -
-
Access Inhibited
No
-
H'0800028A
1 00,01
code
Selection of Non stop operation at instantaneous
power failure
No
b050
H'0800028B
1 0
〜
255
*1
Adjustment of AM(analog monitor)
b080
H'0800028C
1 0
〜
255
*1
Adjustment of FM(digital monitor)
b081
H'0800028D
1 0.5
〜
15.0kHz
*10
Carrier frequency(PWM frequency
0.5
〜
12.0kHz
b083
H'0800028E
1 00
〜
02
code
Selection of Initialization
b084
H'0800028F
1 00
〜
02
code
Selection of initialized data
b085
H'08000290
1 00,01
code
Selection of “STOP” key function
b087
H'08000291
1 00,01
code
Selection free run function
b088
H'08000292
1 00,01
code
Selection of action at stop
b091
H'08000293
1 -
-
Access Inhibited
No
-
H'08000294
1 00,01
code
Selection of action of cooling fan
b092
H'08000295
1 00
〜
02
code
Selection of BRD function
b095
H'08000296
1 00
〜
02
code
Selection of Thermister function
b098
H'08000297
1 00,01
code
Selection of external braking function
No
b120
H'08000298
1 -
-
Access Inhibited
No
-
H'08000299
1 01
〜
48,255
code
Selection of function in Intelligent input 1
01
〜
39,
255
C001
H'0800029A
1 01
〜
48,255
code
Selection of function in Intelligent input 2
01
〜
39,
255
C002
H'0800029B
1 01
〜
48,255
code
Selection of function in Intelligent input 3
01
〜
39,
255
C003
H'0800029C
1 01
〜
48,255
code
Selection of function in Intelligent input 4
01
〜
39,
255
C004
H'0800029D
1 01
〜
48,255
code
Selection of function in Intelligent input 5
01
〜
39,
255
C005
H'0800029E
1 01
〜
48,255
code
Selection of function in Intelligent input 6
No
C006
H'0800029F
1 01
〜
48,255
code
Selection of function in Intelligent input 7
No
C007
H'080002A0
1 01
〜
48,255
code
Selection of function in Intelligent input 8
No
C008
H'080002A1
1 00,01
code
Selection of a(NO) or b(NC) contact in Intelligent
input 1
C011
H'080002A2
1 00,01
code
Selection of a(NO) or b(NC) contact in Intelligent
input 2
C012
H'080002A3
1 00,01
code
Selection of a(NO) or b(NC) contact in Intelligent
input 3
C013
H'080002A4
1 00,01
code
Selection of a(NO) or b(NC) contact in Intelligent
input 4
C014
H'080002A5
1 00,01
code
Selection of a(NO) or b(NC) contact in Intelligent
input 5
C015
H'080002A6
1 00,01
code
Selection of a(NO) or b(NC) contact in Intelligent No
C016