Appendix
Page 28 of 38
B045
1089
1090
Torque limit LADSTOP enable
X1
R/W
0 – 1
B046
1091
1092
Reverse run protection enable
X1
R/W
0 – 1
B050 1099 1100
Controlled deceleration and stop on
power loss
X1
R/W
0 – 1
B051 1101 1102
DC bus voltage trigger level during
power loss
X10
R/W
0 – 10000
B052 1103 1104
Over–voltage threshold during
power loss
X10
R/W
0 – 10000
B053 1105 1106
Deceleration time setting during
power loss
X100
R/W
1 – 360000
B054 1107 1108
Initial output frequency decrease
during power loss
X100
R/W
0 – 1000
B080 1159 1160
[AM] terminal analog meter
adjustment
X1
R/W
0 – 255
B081 1161 1162
[FM] terminal analog meter
adjustment
X1
R/W
0 – 255
B082
1163
1164
Start frequency adjustment
X100
R/W
10 – 999
B083
1165
1166
Carrier frequency setting
X10
R/W
5 – 150 *
B084
1167
1168
Initialization mode
X1
R/W
0 – 2
B085
1169
1170
Country code for initialization
X1
R/W
0 – 2
B086
1171
1172
Frequency scaling factor
X10
R/W
1 – 999
B087
1173
1174
STOP key enable
X1
R/W
0 – 1
B088
1175
1176
Restart mode after FRS
X1
R/W
0 – 1
B090 1179 1180
Dynamic
braking
usage ratio
X10
R/W
0 – 1000
B091
1181
1182
Stop mode selection
X1
R/W
0 – 1
B092
1183
1184
Cooling fan control
X1
R/W
0 – 1
B095 1189 1190
Dynamic
braking
control
X1
R/W
0 – 2
B096
1191
1192
Dynamic braking activation level
X1
R/W
330 – 760 *
B098
1195
1196
Thermistor function
X1
R/W
0 – 2
B099
1197
1198
Thermistor protection level setting
X1
R/W
0 – 9999
B100
1199
1200
Free V/F control frequency 1
X1
R/W
0 – 400
B101
1201
1202
Free V/F control voltage 1
X10
R/W
0 – 8000
B102
1203
1204
Free V/F control frequency 2
X1
R/W
0 – 400
B103
1205
1206
Free V/F control voltage 2
X10
R/W
0 – 8000
B104
1207
1208
Free V/F control frequency 3
X1
R/W
0 – 400
B105
1209
1210
Free V/F control voltage 3
X10
R/W
0 – 8000
B106
1211
1212
Free V/F control frequency 4
X1
R/W
0 – 400
B107
1213
1214
Free V/F control voltage 4
X10
R/W
0 – 8000
B108
1215
1216
Free V/F control frequency 5
X1
R/W
0 – 400
B109
1217
1218
Free V/F control voltage 5
X10
R/W
0 – 8000
B110
1219
1220
Free V/F control frequency 6
X1
R/W
0 – 400
B111
1221
1222
Free V/F control voltage 6
X10
R/W
0 – 8000
B112
1223
1224
Free V/F control frequency 7
X1
R/W
0 – 400
Содержание SJ-EN Ethernet Communications
Страница 2: ...NOTES ...
Страница 4: ...Table of Contents NOTES Page 4 of 38 ...
Страница 8: ...Chapter 1 NOTES Page 8 of 38 ...
Страница 12: ...Chapter 2 NOTES Page 12 of 38 ...
Страница 16: ...Chapter 3 Page 16 of 38 NOTES ...
Страница 18: ...Chapter 4 Page 18 of 38 NOTES ...
Страница 20: ...Appendix Page 20 of 38 NOTES ...
Страница 37: ...Index NOTES Page 37 of 38 ...
Страница 38: ...January 2005 HAL1051A Hitachi America Ltd Tarrytown NY 10591 2005 www hitachi us inverters ...