background image

SINELINK24G

 

 

 14   

 
(1) Fixing to pole   

Arrange pole for this 
product installation. 
 
Pole phi is from 25 to 
45mm. It is 
recommended that pole 
length less than 700mm 
for indoor and less than 
400mm for outdoor 
installation. Confirm 
whether intensity of 
pole is enough for 
installation.  
 
Confirm direction 
adjustment scope for 
availability after the 
installation. Pole is not 
applicable if it interrupt 
with line of sight to the 
scope.   

 

10mm or more

 

Mount bracket : 

 approx. 70mm 

 

 

 

200mm or more

 

 

Fasten mount kit to the 
pole with two M6 bolts 
temporarily. 
 
Insert the bolts to the 
direction indicated by 
the arrow on the right. 
Fasten the bolts to the 
extent this product can 
hold it’s position. For 
precision in direction 
adjustment, the scope 
better be at the position 
where you can look into 
with stable posture.   
 
Pole has to have a 
length more than 
200mm form the bottom 
end of the mount kit. If it 
is shorter than that, 
elevation angle for this 
product might not be 
sufficient for 
adjustment. 
 
 

140mm

以上

M6

ボルトの

差込み方向

 

 
M6 bolt is attached with bolt cap or washer. Position of 
the bolt cap and washer is adjustable. 
 

Direction of M6 bolt

insertion

200mm or more

Содержание SINELINK 24G

Страница 1: ...150Mbps High speed Radio Link User s Manual Please read ahead of the use ...

Страница 2: ...s are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause...

Страница 3: ... 2 INSTALLATION CONNECTION SETTING 5 2 1 INSTALLATION FLOW 5 2 2 SETTING UP FROM PC 6 2 3 PREPARATION FOR INSTALLATION 11 2 4 INSTALLATION 12 2 5 CONNECT TO LAN EQUIPMENTS 20 2 6 CONFIRM THE RF STATUS 20 3 USE OF THIS DEVICE 21 3 1 POWER ON 21 3 2 POWER OFF 21 3 3 MAINTENANCE BY WWW BROWSER 21 4 APPENDIX 33 4 1 SPECIFICATION 33 4 2 RF CHANNEL ALLOCATION NUMBER 35 4 8 FACTORY DEFAULT 36 ...

Страница 4: ...mission speed as optic fiber Enough effective through put to achieve transmission of moving image etc 2 Unlicensed and uncrowded 24GHz band Enough channels availability 8ch Dynamic frequency selection function Avoid using interfered channel and enable the stable circuit quality No license required you can use SINELINK if only the installation has been done 3 High security Data is scrambled Unique ...

Страница 5: ...justed c Heat radiation fin integrated back lid It releases internal heat into air d Mount bracket It fixes this device to pole The diameter of a pole is 25 45mm e LAN connecter Connect LAN cable At the outdoor installation connect LAN cable with waterproofing cap f The atmospheric pressure adjustment hole The atmospheric pressure in this product is adjusted g GND FG Terminal Connect grounding wir...

Страница 6: ...tivity of antenna Directivity of antenna Horizontal direction 0 5 Vertical direction 0 5 Antenna pattern 50 45 40 35 30 25 20 15 10 5 0 30 20 10 0 10 20 30 Angle degree Gain dB 8 7 6 5 4 3 2 1 0 2 1 0 1 2 Angle degree Gain dB ...

Страница 7: ...e serge protective device when you connect outdoor with indoor 3 PoE PSE connects with Switching HUB 4 The terminal GND of SINELINK 24G must connect with grounding conductors 5 Use the Switching HUB corresponding to 100Mbps full duplex 6 Ground it through PoE PSE when you use the STP cable for 2 Outdoor or Indoor Opposite product This product PoE PSE Adapter Switching HUB 5 2 3 Indoor Connect LAN ...

Страница 8: ...a setting environment 2 Change IP Address of PC for setting 3 Setting this product from PC Preparation Prepare in indoor environment before installation 1 Confirm fit of the mounting kit Installation Fix this device to pole Connection Connect this device to LAN equipment Check Wireless Status Confirm the wireless of this device by WWW browser of PC ...

Страница 9: ... negotiation or 100Mbps Full Duplex fixation for setting of connected port with this product Connected port with this product is linked by 100Mbps full duplex Connected port with PC is linked PC for Setting OS Microsoft Windows XP 2000 Professional WWW Browser Microsoft Internet Explorer 6 0 SP1 or above When OS and WWW Browsers other than specification are used this device might not work normally...

Страница 10: ... product 1 To get to setting pages browse to SINELINK 24G by entering the URL in the location bar of your browser The URL is http 192 168 0 202 factory default 2 Enter administrator in the User Name field Do not enter anything in the Password field factory default is none Please set it later 3 Click Settings for Wireless and LAN ...

Страница 11: ... you set Link ID different from the opposite product it can not communicate The field will accept alphanumeric string and has a maximum length of 6 characters Factory default is none IP Address Enter IP Address of this product The range of IP Address is from class A to class C Factory default is 192 168 0 202 This Device Opposite product Point to Point Operation Mode Master Slave Link ID example A...

Страница 12: ...default is Not Use VID Enter VID VLAN ID The range is from 1 to 4094 Factory Default is 1 5 Copy the content of settings each item to paper etc and keep it The setting change and the operation situation cannot be referred to when IP Address and Password etc of this device are forgotten IP Address Classes Range of Subnet Mask Class A 255 0 0 0 255 255 255 252 Class B 255 255 0 0 255 255 255 252 Cla...

Страница 13: ...tting is changed and this device does restart It takes about 30 seconds until restart is completed example 7 Change IP address of PC to the value that can be communicated with this device 8 Confirm settings after this device restarts and pull out LAN cable from this device ...

Страница 14: ...oduct Unless transmission can not be established On the following cases set the marking H upward When you can see opposite product through the scope only when setting H upward due to obstacles No availability of channel in vertical polarization To avoid interference from the other pair of this products nearby To set the H upward remove the four M6 bolts on the rear then rotate the mounting kit 90 ...

Страница 15: ...sight between this products No radio communication is established under such condition Where distance is variable between this products Radio communication is disconnected when the distance varies Installation on automobile crane and the equivalent It might cause device failure Indoor installation example Fix this product to the BS pole stand as shown below when installation is made in doors BS ST...

Страница 16: ...SINELINK24G 13 Outdoor installation example Fix this product to the pole designed for veranda wall and roof top installation depending on circumstances Installation on veranda ...

Страница 17: ... or more 2 Fasten mount kit to the pole with two M6 bolts temporarily Insert the bolts to the direction indicated by the arrow on the right Fasten the bolts to the extent this product can hold it s position For precision in direction adjustment the scope better be at the position where you can look into with stable posture Pole has to have a length more than 200mm form the bottom end of the mount ...

Страница 18: ... the circular cone of 0 5 degrees which centers right angle from the antenna center as shown on the right Adjust the sight of the opposed product in the smaller scope in a range of half radius circle in the opposite end circle 30cm 以上離れて 覗きます アンテナ調整用 スコープ アンテナ調整用 スコープ断面図 見え方 正しい覗き方 2 つの丸が 同心円にな っている 対向装置側の丸 覗き込む側の丸 悪い覗き方 同心円にな っていない 0 5 覗き込む側の丸 対向装置側の丸 対向装置の設置場所 この円内に対向装置 の設置場所が見える ように合わせます Antenn...

Страница 19: ...Adjust the sight of opposite product to the horizontal centre of the hole NG OK NG Vertical center is adjusted by accommodation of vertical angle Visual recognition become harder as longer the distance to opposite products Horizontal angle is to be adjusted to the building of installation in such case Adjust horizontal angle ...

Страница 20: ...of 15 degrees In case of 15 degrees the relation between distance and height will be as follows The opposite product must be viewed at the center of the scope see below NG OK NG If the distance is very long and difficult to adjust please adjust first with the building which the opposite product is settled Distance Height approx 50m 13 4m 100m 26 8m 500m 134m 1 000m 267 9m Vertical angle 15 15 ...

Страница 21: ...bolt so that the Antenna would be stably fixed Fix tightly 7 Next tight the M6 bolt 4pcs to fix the vertical angle of the mounting plate Fixing Torque of M6 bolt should be 2 36 to 2 74 N cm 24 to 28 kgf cm Fix tightly 8 Connect the Grounding cable with M5 screw Grounding terminal FG ...

Страница 22: ...g RJ45 connector to the product Tight certainly the connector by hand Fixing Torque should be 2 26 N m 23 kgf cm To the extent that O ring would be compressed Roll self melting tape and vinyl tape on the water protection cap Wire the LAN cable to the extent that no stress would be add to connector portion Screw in to the extent that O ring would be compressed 15 Connect RJ45 connector to PoE appar...

Страница 23: ...X 100Mbps Full duplex NOTE This product does not support 10Mbps or Semi duplex communication Connection port setting should be Auto Negotiation or 100Mbps Fixed Full duplex NOTE This product does not have filtering function by MAC address etc In case necessary Filtering must be done at LAN equipments of Switching HUB side 2 6 Confirm the RF status RF status can be confirmed through WWW browser of ...

Страница 24: ...es SINELINK 24G to be powered on and start running The power output LED of PoE PSE will light up 3 2 Power Off To power off SINELINK 24G unplug LAN cable plug from IEEE802 3af PoE PSE 3 3 Maintenance by WWW browser Settings and the status confirmation of this device are done by a WWW browser of your PC ...

Страница 25: ...the person who set IP Address to this device when you do not know IP Address example Factory Default 2 Enter User Name and Password User Name is administrator Factory Default of password is none example Factory Default 3 Top page is displayed When you click the item from a left menu the content is displayed right page example Setting SINELINK 24G to Device Name ...

Страница 26: ... Version Current firmware version is displayed MAC Address MAC Address is displayed Serial Number Serial Number of this device is displayed Date Time Date and time of this device is displayed The User needs to set Date Time after Power OFF ON Warning Status Warning Status is displayed Internal Temperature Internal Temperature is displayed ...

Страница 27: ...s into 56M 38M 18Mbps Full Duplex according to Air Data Rate Channel in use Channel in use is displayed Distance Distance in a wireless section with the opposed device is displayed Distance is displayed in 12m step RSSI RSSI of this device or opposed device is displayed SNR SNR Signal to Noise Ratio of this device or opposed device is displayed SNR Margin SNR Margin is displayed Air Data Rate migh...

Страница 28: ... RSSI becomes about 50dBm by ATPC Auto Power Control in the short distance The direction of the antenna might shift when RSSI is lower than a proper value The graph of distance and RSSI theory value 80 70 60 50 10 100 1000 10000 Distance m RSSI dBm Proper value of RSSI when it is not raining 5000 ...

Страница 29: ...tatus page is displayed Link Status Link Status is displayed Link Speed Link Speed is displayed Receive Packets Receive Packets is displayed Receive Errors Receive Errors is displayed Click Clear Counters button Receive Packets and Receive Errors is returned to 0 ...

Страница 30: ...ice Log 1 Click Log Reference Log Reference page is displayed Device Log Device Log is displayed The latest 63 logs from power ON are displayed Click Save button Device Log can be saved to PC Click Clear button All Logs is cleared ...

Страница 31: ...w Password again Enter New Password The field will accept alphanumeric string and has a maximum length of 16 characters Factory default is none 2 Enter new password and click Apply button New Password becomes effective Copy new password to paper etc and keep it The setting change and the operation situation cannot be referred when password of this device are forgotten ...

Страница 32: ...ng Date Time Setting page is displayed Date Time Date and time of this device is displayed The User needs to set Date Time after Power OFF ON New Date Time Enter new date and time 2 Enter new date and time and click Apply button New date and time becomes effective ...

Страница 33: ...tialize the setting 1 Click Initialization Initialization page is displayed Current Setting of this device will be reset to factory defaults and this device does restart It takes about 30 seconds until restart is completed ...

Страница 34: ...re update 2 Enter path and filename click Update button PC starts to send the firmware file to this device Do not power off this device before the update is completed The firmware will be updated and this device does restart It takes about 30 seconds until restart is completed Attention in use Update firmware of this device at your own risk Enter the path and filename for new firmware update ...

Страница 35: ...SINELINK24G 32 10 Restart this device 1 Click Restart button 2 Click OK button It takes about 30 seconds until restart is completed ...

Страница 36: ...r Air data rate Distance Air data rate Mbps Modulation Distance km The adaptive control according to the line quality 150 64QAM 1 100 16QAM 1 5 50 QPSK 2 Throughput Air data rate Mbps Throughput Up Down link Mbps 150 56 56 100 38 38 50 18 18 Delay time Average Air data rate Mbps 64Byte Packets ms 1522Byte Packets ms In case that the load is below throughput 150 Approx 0 7 Approx 1 0 100 Approx 0 7...

Страница 37: ...ntenance can be used Network interface 100BASE TX 100Mbps Full Duplex Packet length 64 1536 byte Power consumption IEEE802 3af PD CLASS 0 conforming 12 95W or less Power supply By overlapped DC PoE Power over Ethernet Cable length within 100m Size Approx 290 W x290 D x70 H mm Without mounting bracket Weight Approx 3 kg Without mounting bracket Built in clock accuracy Error range is from 2 to 3 min...

Страница 38: ...SINELINK24G 35 4 2 RF channel allocation number 24 05GHz CH1 24 08GHz CH2 24 10GHz CH3 24 12GHz CH4 24 14GHz CH5 24 16GHz CH6 24 18GHz CH7 24 20GHz CH8 24 22GHz 24 25GHz ...

Страница 39: ... Name Setting Device Name All space Wireless Settings Operation Mode Slave Link ID none LAN Settings IP Address 192 168 0 202 Subnet Mask 255 255 255 0 Default Gateway none VLAN VLAN Tag Not Used Settings for Wireless and LAN VID 1 Password Change none 2006 3 Rev 1 ...

Отзывы: