4 Electrical checks of main parts
Outdoor unit
SMGB0135 rev.0 - 06/2020
39
4
4.1.3 PCB for power circuit
Voltage specification of power circuit as shown in below table.
Output
Spec
Main load
Measuring point
Example of possible failure mode
5 V 0/P
5
± 0.4
V
Micon,
Thermistor
Tester +
: L105 (JUMPER)
Tester -
: D110 (EARTH)
Outdoor not operate, no blinking indication
12 V 0/P
12
± 0.5
V
Micon,
IC2, 3, 4
Relay circuit
Tester +
: L104 (JUMPER)
Tester -
: D110 (EARTH)
Outdoor not operate, no blinking indication
16 V 0/P
15.5
V
+ 1.5
- 1.0
IPM for Compressor
IPM for DC fan
Tester +
: L103 (JUMPER)
Tester -
: D110 (EARTH)
Stop: LD301 3, 4 or 12 times blinking
B-12 V 0/P
13
V
+ 2.5
- 1.0
Expansion valve
Tester +
: R120 (B-12 V)
Tester -
: R120 (B-0 V)
Stop: LD301 5 times blinking
Power circuit for PCB can consider normal if the result is satisfied with above specification.
4.1.4 Reversing valve control circuit
This control is used to control de ON/OFF state of the relay and the coil, both of the reversing valve.
The ON/OFF state of the relay depends on the operation mode, as shown in the following table.
If the reversing valve is not powered or the conditions do not correspond to the appropriate ones for the operation mode,
it could indicate failure of the control circuit of the reversing valve.
1
2
3
4
R441
R442
DB2
CN2
AC230V
28
27
12V
12V
28
29
Microcomputer
Reversing valve
(4-way Va
lve)
Cooling/Heating switching relay coil
(RL4)
Cooling/Heating
switching relay
(RL4)
Reversing valve
(4-way Valve) relay
(RL3)
Reversing valve
(4-way V
alve) relay
coil (RL3)
Reversing valve
(4-way Valve) on
Reversing valve (4-
way Valve) cooling/
heating switching
Coolin
g Lo
Heating Hi
HIC
Operation mode
Cooling operation
(including forced cooling operation)
(Reference) Heating operation
Tester and CN2 terminal
connection point
⊕
terminal of tester to CN2 pin
terminal of tester to CN2 pin
⊕
terminal of tester to CN2 pin
terminal of tester to CN2 pin
Types of testers
Analog tester
The tester indicates about 80 VDC and returns to 0
V, and indicates about 80 VDC again.
The tester indicates about 160 VDC and returns to
0 V, and indicates about 160 VDC again.
Digital tester
The tester indicates a large value for an instant and
returns to 0 V, and indicates a large value again.
The tester indicates a large value for an instant and
returns to 0 V, and indicates a large value again.
Содержание RAW-35RHC
Страница 1: ...YUTAMPO SERIES Indoor unit YUTAMPO TAW 190 270 RHC Outdoor unit RAW 35RHC Service Manual ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 22: ......
Страница 44: ...4 1 Outdoor unit 4 1 1 Power circuit 4 Electrical checks of main parts Outdoor unit SMGB0135 rev 0 06 2020 36 ...
Страница 58: ......
Страница 88: ......
Страница 93: ......