– 99 –
Inspection method 2
Check the number of times LD301 blinks.
Doesn't blink
Is LD302 blinking?
The SPM2 is broken.
Replace the SPM2.
If the unit doesn't work even after the SPM2 is replaced, the drive circuit may be broken or
the CN14 cable may be cut. Check to see that an electrical current is flowing through the
CN14 cable.
Takes several minutes to restart.
Blinks twice
Yes
LD301: Blinks once
Reset stop
LD301: Blinks twice
Peak current cut
LD301: Blinks three times
Low speed
LD301: Blinks four times
Switch failure
The power source circuit is broken.
Replace the control P.W.B..
Check to see that the MAIN P.W.B. has 17V.
* Be sure to check the correct points for measuring.
Check to see the approximate length of time it takes for
the compressor to stop after switching on and operating
two or three times.
* Wait for three minutes or more before operating.
Check to see the approximate length of time it takes for the
compressor to stop after switching on and operating two or
three times.
* Wait for three minutes or more before operating.
The power source or some other reason may have caused the microcomputer
to reset. Replace the control P.W.B. if the LED blinks once and then stops
frequently during operation.
* The LED blinks once after the power source has been inserted.
There is the possibility that the cycly load has become heavy and the
compressor has come loose. Check the compressor.
* In this case the LED may blink three times before stopping.
There is the chance that the cycle load has become heavy and the
compressor has come loose. Check the compressor.
* In this case the LED may blink twice before stopping.
Yes
Yes
Yes
abnormally
Takes several minutes
to restart.
Restarts quickly
every time.
Restarts quickly every time.
No abnormally
The SPM2 may be broken.
Replace the SPM2.
The SPM2 may be broken.
Replace the SPM2.
Cable abnormally
Cable abnormally
Replace the CN14 cable.
Ia the wire from the SPM2 to the compressor
loose or broken, or has it been connected
improperly?
Ia the wire from the SPM2 to the compressor
loose or broken, or has it been connected
improperly?
Replace the MAIN P.W.B..
No cable abnormally
Doesn't work
even after the
SPM2 is replaced.
Doesn't work even after
the SPM2 is replaced.
Doesn't work
even after the
SPM2 is replaced.
If the unit doesn't work even after replacing the
SPM2, the position detection circuit may be
broken. Replace the MAIN P.W.B..
If the unit doesn't work even after replacing the
SPM2, the drive circuit may be broken. Replace
the MAIN P.W.B..
The compressor switch fails if two or more compressor cables are loose (or
broken).
There is the possibility that the compressor will not operate if the compressor
cables have been connected improperly.
Replace the cable or rewire as appropriate.
In the case that one of the compressor cables has become loose (or
broken), the compressor may work even if it is missing a phase. The
compressor occasionally operates in reverse if one of the compressor
cables has been connected improperly. Replace the cable or rewire as
appropriate.
Cable abnormally
No abnormally
O.K. (16-19V)
No
No
No
No
Содержание RAM-55QH4
Страница 31: ... 30 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 65QH4 ...
Страница 37: ...CIRCUIT DIAGRAM MODEL RAM 55QH4 39 L C023 C022 C002 C001 C025 C024 N ...
Страница 38: ...CIRCUIT DIAGRAM MODEL RAM 65QH4 41 L C023 C022 C002 C001 C025 C024 N ...
Страница 41: ... 45 ...
Страница 47: ... 53 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Страница 48: ... 55 ...
Страница 49: ... 57 ...
Страница 50: ... 59 ...
Страница 51: ... 61 ...
Страница 69: ... 79 5A ...
Страница 76: ... 86 ...
Страница 92: ... 105 ...
Страница 93: ... 106 ...
Страница 99: ... 112 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Страница 100: ... 113 ...
Страница 101: ... 114 ...
Страница 103: ... 116 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Страница 104: ... 117 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 55QH4 MODEL RAM 65QH4 ...
Страница 109: ...HITACHI PM NO 0217E Printed in Malaysia RAM 55QH4 RAM 65QH4 ...