– 15 –
Indoor unit 1
Outdoor unit
Outdoor unit
Maximum 5m
Maximum
±
10m
Indoor unit
Indoor unit
Indoor unit
Indoor unit 2
Indoor unit 3
INSTALLATION
PIPE LENGTH
(1) Total 45m maximum pipe length.
(2) Pipe length for one indoor unit : maximum 25m.
HIGHT DIFFERENCE
(1) Hight : maximum
±
10m
(2) Hight difference between each indoor unit
≤
5m.
L
1
L
2
L
3
To the outdoor unit, up to three indoor units can be connected until the total value of
capacity from 5.0kW to 9.0kW.
Make sure to connect to two or three indoor units.