– 21 –
CONSTRUCTION AND DIMENSIONAL DIAGRAM
MODEL RAM-53QH5
Handle
Air suction
grille
104
64
26
850
79
22
20
Indoor unit 1
Service valve (ø6.35)
Indoor unit 2
Service valve (ø6.35)
Indoor unit 3
Service valve (ø6.35)
Indoor unit 1
Service valve (ø9.52)
Indoor unit 2
Service valve (ø9.52)
Indoor unit 3
Service valve (ø9.52)
298
340
Unit: mm
201
107.5
52
52
52
52
52
650
638
Air outlet
10
10
10
320
340
Holes for anchor bolt
(2-ø12)
Fixing hole
507
198
57
12
37
Notch for anchor bolt
(2-ø12 Notchs)
More than
More than
More than
100
More than
700
100
100
Service space
ATTENTION
During service, before opening the side cover, please switch off power supply.
Note:
1. Insulated pipes should be used for both small and large diameter pipes.
2. Piping length should be within 25m for one room and within 45m in total.
3. Height difference of piping between indoor unit and outdoor unit should be within 10m.
4. Overhead clearance of outdoor unit should be 200mm to allow servicing.
5. For electrical connection, please refer to the installation manual.
Содержание RAM-52QH5
Страница 16: ... 15 MODEL RAM 52QH5 ...
Страница 17: ... 16 MODEL RAM 53QH5 ...
Страница 30: ... 29 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 53QH5 ...
Страница 36: ...CIRCUIT DIAGRAM MODEL RAM 52QH5 39 L C023 C022 C002 C001 C025 C024 N ...
Страница 37: ...CIRCUIT DIAGRAM MODEL RAM 53QH5 41 L C023 C022 C002 C001 C025 C024 N ...
Страница 40: ... 45 ...
Страница 42: ... 49 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Страница 43: ... 51 ...
Страница 44: ... 53 ...
Страница 45: ... 55 ...
Страница 46: ... 57 ...
Страница 58: ... 69 REFRIGERATING CYCLE DIAGRAM RAM 52QH5 ...
Страница 59: ... 70 REFRIGERATING CYCLE DIAGRAM RAM 52QH5 ...
Страница 60: ... 71 REFRIGERATING CYCLE DIAGRAM RAM 53QH5 ...
Страница 61: ... 72 REFRIGERATING CYCLE DIAGRAM RAM 53QH5 ...
Страница 64: ... 75 5A ...
Страница 67: ... 78 3 System power Module Circuit ...
Страница 71: ... 82 ...
Страница 72: ... 83 5 Reversing valve control circuit Fig 5 1 ...
Страница 75: ... 86 8 Overload control circuit OVL control circuit Fig 8 1 Overload Control System Configuration Fig 8 2 ...
Страница 87: ... 101 ...
Страница 88: ... 102 ...
Страница 94: ... 108 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Страница 95: ... 109 ...
Страница 96: ... 110 ...
Страница 98: ... 112 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Страница 99: ... 113 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 53QH5 MODEL RAM 52QH5 ...
Страница 104: ...HITACHI PM NO 0428E Printed in Malaysia RAM 52QH5 RAM 53QH5 ...