– 11 –
DUAL SYSTEM MULTI R.A.C.
RAM-52QH5
CONNECTING POSISION TO BE ABLE TO INSTALL
POSSIBLE COMBINATIONS
TO INSTALL
(kW)
CONNECTING POSITION ON
OUTDOOR UNIT
(VALVE DIAMETER)
(mm)
No.1
No.2
SUITABLE ROOM SIZE
TO INSTALL
(m
2
)
6.35/9.52D
6.35/9.52D
TWO UNITS
1.8+1.8
1.8+2.5
1.8+3.5
1.8+5.0
2.5+2.5
2.5+3.5
(8-12) + (8-12)
(8-12) + (10-16)
(7-9) + (15-22)
(6-9) + (18-27)
(12-15) + (12-15)
(11-14) + (14-18)
1.8
1.8
1.8
1.8
2.5
2.5
1.8
2.5
3.5
5.0
2.5
3.5
2.5, 3.5, 4.0, 5.0 means indoor units cooling capacity class.
(1) Marking
: needs flare adapter (9.52 12.7D): Part No. TA261D-4 001
(2) Suitable room size is determined based on the conditions below:
• Climate is in the temperate zone like Tokyo, Japan.
• For usual residential use.
• Smaller figure is for light construction which means light thermally sealed.
• Larger figure is for heavy constructions, which means well thermally sealed.
3.5+3.5
(13-16) + (13-16)
3.5
3.5
2.5+5.0
(10-12) + (18-20)
2.5
5.0
Содержание RAM-52QH5
Страница 16: ... 15 MODEL RAM 52QH5 ...
Страница 17: ... 16 MODEL RAM 53QH5 ...
Страница 30: ... 29 CAPACITY DIAGRAM RELATED TO THE PIPING LENGTH MODEL RAM 53QH5 ...
Страница 36: ...CIRCUIT DIAGRAM MODEL RAM 52QH5 39 L C023 C022 C002 C001 C025 C024 N ...
Страница 37: ...CIRCUIT DIAGRAM MODEL RAM 53QH5 41 L C023 C022 C002 C001 C025 C024 N ...
Страница 40: ... 45 ...
Страница 42: ... 49 Outdoortemperature STAROTP_C TSKTM1_C1 Outdoortemperature STAROTP_C TSKTM1_C2 ...
Страница 43: ... 51 ...
Страница 44: ... 53 ...
Страница 45: ... 55 ...
Страница 46: ... 57 ...
Страница 58: ... 69 REFRIGERATING CYCLE DIAGRAM RAM 52QH5 ...
Страница 59: ... 70 REFRIGERATING CYCLE DIAGRAM RAM 52QH5 ...
Страница 60: ... 71 REFRIGERATING CYCLE DIAGRAM RAM 53QH5 ...
Страница 61: ... 72 REFRIGERATING CYCLE DIAGRAM RAM 53QH5 ...
Страница 64: ... 75 5A ...
Страница 67: ... 78 3 System power Module Circuit ...
Страница 71: ... 82 ...
Страница 72: ... 83 5 Reversing valve control circuit Fig 5 1 ...
Страница 75: ... 86 8 Overload control circuit OVL control circuit Fig 8 1 Overload Control System Configuration Fig 8 2 ...
Страница 87: ... 101 ...
Страница 88: ... 102 ...
Страница 94: ... 108 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Страница 95: ... 109 ...
Страница 96: ... 110 ...
Страница 98: ... 112 three three inlet 3 Cut off the three pipes at the side and bottom of Reversing valve ...
Страница 99: ... 113 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 53QH5 MODEL RAM 52QH5 ...
Страница 104: ...HITACHI PM NO 0428E Printed in Malaysia RAM 52QH5 RAM 53QH5 ...