![Hitachi RAM-35QH5 Скачать руководство пользователя страница 68](http://html.mh-extra.com/html/hitachi/ram-35qh5/ram-35qh5_service-manual_2139479068.webp)
– 74 –
SPM2
Smoothing Capacitors
(C501, C502, C503)
Reactor
Diode stack
(D25 VB60)
Switching Power P.W.B.
(For Indoor P.W.B)
Service switch
Control P.W.B.
Power P.W.B.
Terminal
Board (2p)
Terminal
Board (4p)
1. Turn off the power switch of indoor unit or disconnect power plug.
2. Wait for 10 minutes or more after power is turned off and then remove electrical parts box lid. As shown
below, Apply soldering iron of 30-75W for 15 seconds or more to P1 and N1 black/white lead receptacles
on system power module to discharge voltage from smoothing capacitor.
Do not loosen or remove screws of system power module: If screw is loose, voltage will not be discharged.
3. Before operation check of each part of circuit, remove receptable of red/gray lead connected to system power
module from diode stack.
Caution:
●
Voltage of about 360V is charged at both ends of smoothing capacitors 400
µ
F X 3.
●
High voltage (DC 360V) is also charged at screw and terminal sactions of system power module.
●
During continuity check for each circuit of electrical parts in outdoor unit is performed, to prevent
secondary trouble, disconnect red/gray wire connected to system power module (SPM2) from
diode stack. (Also be sure to perform discharging of smoothing capacitor.)
Do not use soldering iron with
transfor mer : Doing so will blow
thermal fuse inside transformer.
DISCHARGE PROCEDURE AND HOW TO CUT OFF POWER TO POWER CIRCUIT
WARNING
As shown left, apply soldering iron to metal
parts (receptacles) in sleeve corresponding
to P1 and N1 terminals of system power
module (SPM2).
Screws of system power module (SPM2) are live parts: Do
not touch them. Screw tightening torque and method are strictly
specified.
When the screw is loosened or removed once, be sure to
tighten according to the procedure shown on the right, with
tightening torque of 0.8
±
0.2 N · m.
Содержание RAM-35QH5
Страница 9: ... 8 ...
Страница 10: ... 9 MODEL RAM 40QH5 ...
Страница 11: ... 10 ...
Страница 12: ... 11 AC 220V 240V ONLY L N INDOOR 1 C1 D1 C2 D2 INDOOR 2 ...
Страница 13: ... 12 ...
Страница 21: ... 20 MODEL RAM 40QH5 WIRING DIAGRAM OUTDOOR UNIT ...
Страница 23: ...PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAM 40QH5 23 MOUNTING PCB SET TYPE ...
Страница 25: ... 27 heating ff BASIC MODE MODEL RAM 40QH5 ...
Страница 28: ... 33 Table 6 Table 7 ...
Страница 29: ... 35 ...
Страница 31: ... 37 ...
Страница 56: ... 62 Fig 11 2 ...
Страница 69: ... 75 1 Outdoor unit does not operate remote control signal can be received RAM 40QH5 ...
Страница 71: ... 77 Lighting mode self diagnosis lamp 2 RAM 40QH5 ...
Страница 72: ... 78 TROUBLESHOOTING OF THE SYSTEM POWER MODULE ...
Страница 73: ... 79 ...
Страница 74: ... 80 ...
Страница 75: ... 81 ELECTRIC EXPANSION VALVE PIPE THERMISTOR POSITION CHARTS MODEL RAM 40QH5 ...
Страница 78: ...HITACHI PM NO 0270E Printed in Malaysia RAM 40QH5 ...