background image

– 2 –

SAFETY PRECAUTION

 

Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.

 

Pay special attention to signs of “

!

Warning

” and “

!

Caution

”. The “Warning” section contains matters which, if not 

observed strictly, may cause death or serious injury. The “Caution” section contains matters which may result in serious 
consequences if not observed properly. Please observe all instructions strictly to ensure safety.

 

The sign indicate the following meanings.

 

Make sure to connect earth line.

 

The sign in the 

fi

 gure indicates prohibition.

  Indicates the instructions that must be followed.

 

Please keep this manual after reading.

PRECAUTIONS DURING OPERATION

 

Avoid an extended period of direct air 

fl

 ow for your health.

W

A
R
N

I

N
G

!

 

Do not insert a 

fi

 nger, a rod or other objects into the air outlet or inlet. As the fan is rotating 

at a high speed, it will cause injury. Before cleaning, be sure to stop the operation and turn 
the breaker OFF.

 

Do not use any conductor as fuse wire, this could cause fatal accident.

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

  Should abnormal situation arises (like burning smell), please stop operating the unit and turn 

off the circuit breaker. Contact your agent. Fault, short circuit or 

fi

 re may occur if you continue 

to operate the unit under abnormal situation.

  

Please contact your agent for maintenance. Improper self maintenance may cause electric 
shock and 

fi

 re.

  

Please contact your agent if you need to remove and reinstall the unit. Electric shock or 

fi

 re 

may occur if you remove and reinstall the unit yourself improperly.

  

If the supply cord is damaged, it must be replaced by the special cord obtainable at 

 

authorized service/parts centers.

W

A
R
N

I

N
G

!

 

 

During thunder storm, disconnect and turn off the circuit breaker.

WARNING

PRECAUTIONS DURING INSTALLATION

  Do not reconstruct the unit.

 

Water leakage, fault, short circuit or 

fi

 re may occur if you reconstruct the unit by yourself.

  Please ask your sales agent or quali

fi

 ed technician for the installation of your unit. Water 

leakage, short circuit or 

fi

 re may occur if you install the unit by yourself.

  Please use earth line.

  Do not place the earth line near water or gas pipes, lightning-conductor, or the earth 

line of telephone. Improper installation of earth line may cause electric shock.

  Be sure to use the speci

fi

 ed piping set for R410A. Otherwise, this may result in broken 

copper pipes or faults.

  A circuit breaker should be installed depending on the mounting site of the unit. Without 

a circuit breaker, the danger of electric shock exists.

  Do not install near location where there is 

fl

 ammable gas. The outdoor unit may catch 

fi

 re  if 

fl

 ammable gas leaks around it.

  Please ensure smooth 

fl

 ow of water when installing the drain hose.

CAUTION

!

!

RAI-25QPB-UM-EN2   2

RAI-25QPB-UM-EN2   2

12/23/14   5:10 PM

12/23/14   5:10 PM

Содержание RAI-25QPB

Страница 1: ...CEILING CASSETTE TYPE AIR CONDITIONER INDOOR UNIT RAI 25QPB RAI 35QPB RAI 50QPB INDOOR UNIT MODEL RAI 25QPB RAI 35QPB RAI 50QPB RAI 25QPB UM EN1 1 RAI 25QPB UM EN1 1 12 23 14 5 09 PM 12 23 14 5 09 PM ...

Страница 2: ...uation Please contact your agent for maintenance Improper self maintenance may cause electric shock and fire Please contact your agent if you need to remove and reinstall the unit Electric shock or fire may occur if you remove and reinstall the unit yourself improperly If the supply cord is damaged it must be replaced by the special cord obtainable at authorized service parts centers W A R N I N G...

Страница 3: ...atically for a long period of time water will condense on the air deflector and drips down occasionally This will wet your furniture Therefore do not operate under such condition for a long time If the amount of heat in the room is above the cooling or heating capability of the unit for example more people entering the room using heating equipments and etc the preset room temperature cannot be ach...

Страница 4: ...TLET REMOTE CONTROL Send out operation signal to the indoor unit So as to operate the whole unit Refer Remote Controller Manual Recommended to replace the air cleaning filter after every 3 months for normal usage Type number for this air cleaning filter is SPX NTW1 Please use this number for ordering when you want to renew it NOTE WIDTH mm 580 MODEL RAI 25QPB 35QPB 50QPB HEIGHT mm 285 DEPTH mm 580...

Страница 5: ... unit will also start to cool or dehumidify OPERATING RANGE Operation mode Outdoor temperature Cooling Dehumidifying 10 to 43 C Heating 15 to 21 C Several indoor units can be connected to one outdoor unit You can operate only one unit or several units according to your needs Adjusting the Number of Indoor Units Decrease the number of indoor units to be operated especially when it is very hot or co...

Страница 6: ...ed for a total of about 200 hours the FILTER lamp lights to indicate that it is time to clean the filter The lamp goes out when the AUTO SWING button is pressed while the device is on STANDBY MODE TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work Use non conductor stick example toothpick By pressing the temporary switch the operation is done in previously ...

Страница 7: ...elow Cooling Heating Minimum Maximum Minimum Maximum Indoor Dry bulb C 21 32 20 27 Wet bulb C 15 23 12 19 Outdoor Dry bulb C 21 43 2 21 Wet bulb C 15 26 1 15 CIRCUIT BREAKER When you do not use the room air conditioner set the circuit breaker to OFF A9R127606 tmp 5 1 13 15 9 40 AM ...

Страница 8: ...p time in the morning This will enable you to enjoy a comfortable room temperature Please use the timer effectively Dusty air filter will reduce the air volume and the cooling efficiency To prevent from wasting electric energy please clean the filter every 2 weeks Please pay attention to the room temperature and air flow direction when operating the unit for baby children and old folks who have di...

Страница 9: ...lease switch off the power from the mains If the power from mains remains ON the indoor unit still consumes about 12W depends on outdoor unit connected in the operation control circuit even if it is in OFF mode Warning To protect the whole unit during lightning please stop operating the unit and remove the plug from the socket Interference From Electrical Products Caution To avoid noise interferen...

Страница 10: ...neutral detergent After using neutral detergent wash with clean water and dry in the shade 3 Install the filter Set it with UP SIDE mark facing front Slot the filter to suction grille and close as original state Press the mark PUSH at the left and right sides of the suction grille to fix it securely CAUTION Do not wash with hot water at more than 40 C The filter may shrink When washing it shake of...

Страница 11: ...When it is excessively dirty wipe with soft cloth soaked in lukewarm water or neutral detergent Then wipe thoroughly with a soft dry cloth CAUTION Do not splash or direct water to the body of the unit when cleaning it as this may cause short circuit Never use hot water above 40 C benzine gasoline acid thinner or a brush because they will damage the plastic surface and the coating 3 MAINTENANCE AT ...

Страница 12: ... the room air conditioner because the various odor emitted by smoke foodstuffs cosmetics and so on sticks to it So the air filter and the evaporator regularly must be cleaned to reduce the odor Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your unit production number date of installat...

Страница 13: ... 121 MUISTIINPANOT A9R127606 tmp 119 1 13 15 9 40 AM ...

Страница 14: ... 122 MUISTIINPANOT A9R127606 tmp 120 1 13 15 9 40 AM ...

Отзывы: