– 63 –
2. Only indoor fan does not operate (other is normal)
Is approx 20 V DC generated
between pins
2
(blue) and
4
(red)
of CN 10 when operated at high fan
speed during cooling?
Are pulses of approx. 33 Vp-p
generated at the collectors of Q901
in the fan operation mode? Are
collectors of Q903 approx.
O V?
Are microcomputer fan PWM
outputs (micro computer pins
24
)“Hi”
or are pulses output
in the fan operation mode?
Has the fan been stopped by
remote control?
Are microcomputer fan PWM
outputs micro computer pins
54
“Hi”?
Is 5 V DC generated between pins
2
(blue) and
1
(yellow) of CN10?
Is there 1 or less between L901
and L902?
Replace indoor fan motor.
Check disconnection, etc of lead
wires.
Replace Q901.
Replace L901.
Replace Q903.
Replace micro computer.
Perform final operation check.
Replace micro computer.
Replace Q903.
Replace Q901.
Replace micro computer.
Replace micro computer.
Replace the air deflector motor.
Replace IC111.
Perform final operation check.
Perform final operation check.
Is there a voltage higher than 15V
across C114 (12 V line)?
Is pulse signal output to micro
computer pins
%
~
™
with air
deflector set to auto during cooling?
No
Yes
No
No
Are the collectors of Q903 approx
OV?
No
No
Yes
No
Yes
No
No
Yes
Yes
No
Yes
Yes
Yes
3. Indoor fan speed does not change (other is normal)
4. Air deflector does not move (other is normal)
No
Yes
Yes
Содержание RAI-25NH5A
Страница 28: ... 26 MEMO ...
Страница 31: ... 29 Wired Remote Control Weekly Timer MODEL RAI 25NH5A RAI 35NH5A RAI 50NH5A WIRING DIAGRAM INDOOR UNIT ...
Страница 33: ...CIRCUIT DIAGRAM MODEL RAI 25NH5A RAI 35NH5A RAI 50NH5A 33 ...
Страница 35: ... 37 47 RAI 25NH5A RAI 35NH5A RAI 50NH5A ...
Страница 56: ... 65 CHECKING THE REMOTE CONTROLLER ...
Страница 61: ...HITACHI PM NO 0401E Printed in Malaysia RAI 25NH5A RAI 35NH5A RAI 50NH5A ...