– 15 –
FAN SPEED (AUTO)
..... When the AUTO fan speed mode is set in the cooling/heating operation:
For the heating operation
●
The fan speed will automatically change according to the temperature
of discharged air.
●
When the difference of room temperature and setting temperature is
large, fan starts to run at HI speed.
●
When the room temperature reaches setting temperature, fan speed
changes to LOW automatically.
●
When the difference of room temperature and setting temperature is
large, fan starts to run at HI speed.
●
After room temperature reaches the preset temperature, the cooling
operation, which changes the fan speed and room temperature to obtain
optimum conditions for natural healthful cooling will be performed.
For the cooling operation
FAN OPERATION
You can use the device simply as an air circulator. Use this function to dry the interior of the indoor
unit at the end of summer.
Press the FUNCTION selector so that the display indicates
(FAN).
Press the (FAN SPEED) button.
(HI)
: The strongest air blow.
(MED)
: Fan speed slow.
(LOW)
: Fan speed slower.
(SILENT) : Fan speed ultra slower.
Press the (START/STOP) button. Fan operation starts with
a beep. Press the button again to stop operation.
1
2
START
STOP
Содержание RAI-25NH5A
Страница 28: ... 26 MEMO ...
Страница 31: ... 29 Wired Remote Control Weekly Timer MODEL RAI 25NH5A RAI 35NH5A RAI 50NH5A WIRING DIAGRAM INDOOR UNIT ...
Страница 33: ...CIRCUIT DIAGRAM MODEL RAI 25NH5A RAI 35NH5A RAI 50NH5A 33 ...
Страница 35: ... 37 47 RAI 25NH5A RAI 35NH5A RAI 50NH5A ...
Страница 56: ... 65 CHECKING THE REMOTE CONTROLLER ...
Страница 61: ...HITACHI PM NO 0401E Printed in Malaysia RAI 25NH5A RAI 35NH5A RAI 50NH5A ...