10.1.2.
ERROR CODE INFORMATION
1. In case failure occurs to the air conditioner, the error code will constantly appear on the wired remote controller
display.
TIMER
L
LAMP
BLINKING
LD301
B
BLINKING
CODE
MEANING
INDOOR
- -
-
Normal
1 time
Refrigerant cycle fault
2 times
-
-
Outdoor unit is under forced operation
3 times
9 times
Communication error between indoor and outdoor
units
9 times
-
Indoor thermistor
10 times
-
Abnormal rotating numbers
13 times
-
IC401 data reading error
OUT
D
OOR
4 times
2 times
Peak current cut
4 times
3 times
Compressor abnormal low speed rotation
4 times
4 times
Compressor switching failure
4 times
5 times
-
Overload lower limit cut