![Hitachi RAC-35WPC Скачать руководство пользователя страница 29](http://html.mh-extra.com/html/hitachi/rac-35wpc/rac-35wpc_technical-catalogue_139697029.webp)
CONTROL AND FUNCTION
27
9
9.9.
ADDITIONAL FUNCTION VIA DIP-SWITCH SETTINGS
A new DIP Switch is available on the PWBs of the indoor unit that provide additional functions via the settings on the switches.
ON
Air conditioner IIndoor PWB
䊾
OFF
Pin No.
Function
Switch Position / Setting
1
AUTO RESTART function
OFF
Enable
ON
Disable
2
DRY
CONTACT
function
OFF Disable
ON Enable
3
DRY CONTACT Logic Select
OFF
HI Input
Active
ON
LO Input
Active
4
HEATING / COOLING ONLY
MODE SELECT
OFF
NORMAL
(HEAT
AND
COOL)
OFF
HEATING
ONLY
ON
COOLING ONLY
5 OFF
ON
OFF
6 REMOCON
ID
SELECT
1 OFF
SELECT
ID A
ON
SELECT ID
B
NOTE:
1 The setting of pin no. 6 is disabled for this model. Please refer to 9
9.5 SETTING THE PREVENTION OF MUTUAL
INTERFERENCE.
9.9.1.
AUTO RESTART FUNCTION
The AUTO RESTART function can be enabled or disabled by setting Pin No. 1 on the DIP SWITCH above to the ON or OFF
position accordingly.
9.9.2.
HEATING/COOLING ONLY MODE SELECTION
When this function is enabled, the operation mode could be locked to either Heating Only (Heating or Fan) or Cooling Only
(Cooling, Fan or Dehumidifying) by setting the Pin No. 4 and 5 accordingly.
LOCKED MODE
REMARKS
HEATING ONLY
Unit will not enter into Cooling mode although cooling mode is selected using the remote controller.
COOLING ONLY
Unit will not enter into Heating mode although heating mode is selected using the remote controller.
DIP SW Label
Содержание RAC-35WPC
Страница 1: ...TECHNICAL CATALOGUE MONO SPLIT RAC 35WPC RAK 35RPC RAK 50RPC RAC 50WPC ...
Страница 18: ...WIRING DIAGRAM 16 7 7 WIRING DIAGRAM 7 1 RAK 35RPC RAK 50RPC ...
Страница 19: ...WIRING DIAGRAM 17 7 7 2 RAC 35WPC ...
Страница 20: ...WIRING DIAGRAM 18 7 7 3 RAC 50WPC ...
Страница 42: ...HITACHI TC ERP Model INDOOR OUTDOOR RAK RAC 50WPC RAC 35WPC 50RPC RAK 35RPC ...