Checking points
·
Direct sunlight and other intense light make the remote control light-receiving unit less sensitive.
·
Check for any time zone where the remote control light-receiving unit of the indoor unit is affected by
ǂ
direct sunlight depending on the location of the sun and mirror reflection.
Actions proposed
·
Block the sunlight to protect against direct sunlight.
Checking points
·
Using a wireless transmitter near the air-conditioner may affect the reception of remote control signals.
·
Have your users try sending signals with a wireless transmitter and examine their effects on the
ǂ
reception of remote control signals.
Actions proposed
·
Add a ferrite core to the power cord and F cable.
·
Add a ferrite core to the internal wiring of the indoor unit.
·
Move the wireless antenna.
Checking points
·
Check the effects of light and power noises coming from other electrical products.
·
Turn on and off the electrical products, turn off the power and turn on the power, and check their effects
on the reception of remote control signals.
·
For products whose operating states change, check the effects of each state.
Actions proposed
·
Change the location relationship between the air-conditioner and the target products.
·
Use a different wall outlet for the target products.
Checking points
·
Check for effects of electrical noises coming into the air-
ǂ
conditioner through grounding wires.
·
Check if the grounding works is for the air-conditioner alone or
ǂ
shared with other equipment. If there is any equipment that
ǂ
shares it, turn on and off that equipment and detach and
ǂ
reattach the power plugs and examine their effects on the
ǂ
reception of remote control signals.
Actions proposed
·
Establish an independent grounding for the air-conditioner.
Effects of other
electrical products
Sharing
a grounding
Air-conditioner
Other
equipment
Grounding
Effects of radio
waves
Effects of direct
sunlight
77
Содержание RAC-35WPC
Страница 23: ...23 ...
Страница 24: ...24 ...
Страница 25: ...25 ...
Страница 26: ...26 ...
Страница 27: ...27 ...
Страница 30: ...WIRING DIAGRAM RAK 35RPC RAK 50RPC 30 ...
Страница 32: ...CIRCUIT DIAGRAM MODEL WIRED REMOTE CONTROL SEND RAK 35RPC RAK 50RPC POWER FOR CLEANNESS 32 ...
Страница 53: ...10 10 10 10 R901 R904 R641 R907 R908 R694 R902 R695 R741 R740 R642 DSW1 DSW1 R903 R905 R906 9 53 ...
Страница 63: ...64 63 ...
Страница 66: ...35 and page 36 66 ...
Страница 67: ...Please set the DIP switch No 6 to ON accordingly Refe to page r RAR 6N1 RAR 6N2 RAR 6N3 RAR 6N4 RAR 6N5 53 67 ...
Страница 68: ...5 68 3 ...
Страница 69: ...69 ...
Страница 86: ...HHAW NO 0096E RAK 35RPC RAK 50RPC 86 ...