WARNING

SAFETY PRECAUTION

  Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.

  Pay special attention to signs of “

 Warning

” and “

 Caution

”. The “Warning” section contains matters which, 

if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may 

result in serious consequences if not observed properly. Please observe all instructions strictly to ensure 

safety.

  The signs indicate the following meanings. (The following are examples of signs.)

  Please keep this manual after reading.

  Do not reconstruct the unit.

  Water leakage, fault, short circuit or fire may occur if you reconstruct the unit by 

yourself.

  Please ask your sales agent or qualified technician for the installation of your unit.  

Water leakage, short circuit or fire may occur if you install the unit by yourself.

  Please use earth line.

  Do not place the earth line near water or gas pipes, lightning-conductor, or the 

earth line of telephone. Improper installation of earth line may cause electric 
shock.

  Be sure to use the specified piping set for R410A. Otherwise, this may result in 

broken copper pipes or faults.

  A circuit breaker should be installed depending on the mounting site of the unit. 

Without a circuit breaker, the danger of electric shock exists.

  Do not install the unit near a location where there is flammable gas.  

The outdoor unit may catch fire if flammable gas leaks around it. Piping shall be 
suitable supported with a maximum spacing of 1m between the supports.

  Please ensure smooth flow of water when installing the drain hose. If any failure 

is found in the drain path, water drops from the indoor and outdoor units, causing 
wet household effects.

  Make sure that a single phase 230V power source is used.

  The use of other power sources may cause electrical components to overheat 

and lead to fire.

PROHIBITION

CONNECT EARTH LINE

PROHIBITION

PROHIBITION

WARNING

CAUTION

  Avoid an extended period of direct air flow for your health.

  Should  abnormal  situation  arise  (like  burning  smell),  please  stop  operating  the   

unit and remove plug from the socket or turn off the circuit breaker. Contact your 
agent.  Fault,  short  circuit  or  fire  may  occur  if  you  continue  to  operate  the  unit   
under abnormal situation.

  Please contact your agent for maintenance.  

Improper self maintenance may cause electric shock and fire.

  Please contact your agent if you need to remove and reinstall the unit.  

Electric shock or fire may occur if you remove and reinstall the unit yourself improperly.

PROHIBITION

“OFF”

PRECAUTIONS DURING INSTALLATION

PRECAUTIONS DURING SHIFTING OR MAINTENANCE

 Do not connect the power calbe with an extension cable or do not plug too many 

leads of the other electric appliance into the socket where this cable is plugged.  
In addition, wire the cable with some allowances to prevent the cable from stretching.
Not doing so will cause an electrical shock, heat generation or fire.

  This sign in the figure indicates prohibition. 

  Indicates the instructions that must be followed.

  Do not bundle the power cable, pull it, put something on it, heat it, process it, or 

put it between things. Breakage of the power cable may result.  
Use of a damaged cable may cause an electrical shock or a fire.

  Do not put objects like thin rods into the panel of blower and suction side 

because the high-speed fan inside may cause danger.

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

Содержание RAC-25YHA

Страница 1: ...NDOOR UNIT Instruction manual To obtain the best performance and ensure years of trouble free use please read this instruction manual completely OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT RAS 25YHA RAS 35YHA RAC 25YHA RAC 35YHA SPLIT TYPE AIR CONDITIONER ...

Страница 2: ... water drops from the indoor and outdoor units causing wet household effects Make sure that a single phase 230V power source is used The use of other power sources may cause electrical components to overheat and lead to fire PROHIBITION CONNECT EARTH LINE PROHIBITION PROHIBITION WARNING CAUTION Avoid an extended period of direct air flow for your health Should abnormal situation arise like burning s...

Страница 3: ...unit with wet hands this could cause fatal accident DON T WET When operating the unit with burning equipments regularly ventilate the room to avoid oxygen insufficiency Do not direct the cool air coming out from the air conditioner panel to face household heating apparatus as this may affect the working of apparatus such as the electric kettle oven etc PROHIBITION Please ensure that outdoor mountin...

Страница 4: ... the indoor unit to the outdoor during cooling or dehumidifying operation Piping and Wiring Air inlets Rear and left sides Air outlet When heating operation is performed cool air blows and when cooling or dehumidifying operation is performed warm air blows Drain port Bottom Earth terminal Lower section of the side About the outdoor unit When Stop is selected during operation of the indoor unit the...

Страница 5: ... automatic operation once power is switched on Turn off the circuit breaker or pull out the power plug if the unit is not be operated for a long period If the power stays on and the unit is not operated power is slightly consumed in the control circuit The power is saved by turning off the power switch or the circuit breaker when the power is supplied from the outdoor unit Attaching the air cleans...

Страница 6: ... press this button the intensity of circulation will change from AUTO to HI to MED to LOW This button allows selecting the optimal or preferred fan speed for each opera tion mode SLEEP button Use this button to set the sleep timer TEMPERATURE buttons Use these buttons to raise or lower the temperature setting Keep pressed and the value will change more quickly TIME button Use this button to set an...

Страница 7: ...on the current room temperature When AUTO is first selected the device will determine thecurrent room temperature and select the proper operationmode accordingly When the air conditioner has adjusted the room s temperatureto the near preset temperature it will begin to monitoroperation If the room temperature subsequently changes the air conditioner will once again select the appropriateoperation h...

Страница 8: ...hat the display indicates HEAT As the settings are stored in memory in the remote controller you only have to press the START STOP button next time Set the desired room temperature with the TEMPERATURE buttons the display indicates the setting The temperature setting and the actual room temperature may vary somewhat depending on conditions Press the START STOP button Heating operation starts with ...

Страница 9: ... that the display indicates DEHUMIDIFY The FAN SPEED is set at LOW automatically The FAN SPEED button does not work Press the START STOP button 1 Dehumidifying Function START STOP Dehumidifying takes place with a target temperature which is slightly lower than the room temperature setting However target temperature is 16 C for a temperature setting of 16 C If the room temperature becomes lower tha...

Страница 10: ...RATURE buttons the display indicates the setting The temperature setting and the actual room temperature may vary somewhat depending on conditions Press the START STOP button Cooling operation starts with a beep Press the button again to stop operation The cooling function does not start if the temperature setting is higher than the current room temperature even though the OPERATION lamp lights Th...

Страница 11: ...ll automatically change according to the temperature of discharged air As room temperature reaches the preset temperature a very light breeze will blow Operation starts in the HI mode to reach the preset temperature As room temperature approaches the preset temperature fan speed au tomatically switches to LOW Press the START STOP button Fan operation starts with a beep Press the button again to st...

Страница 12: ...e TIMER control button Press the RESERVE button 3 Press the ON TIM ER button so that the OFF mark lights and the ON mark blinks The device will turn on off and off on at the designated times The switching occurs first at the preset time that comes earlier The arrow mark appearing on the display indicates the sequence of switching operations How to Cancel Reservation Point the signal window of the r...

Страница 13: ... The timer may be used in three ways off timer on timer and ON OFF OFF ON timer Set the current time at first because it serves as a reference As the time settings are stored in memory in the remote controller you only have to press the RESERVE button is order to use the same settings next time 2 Set the TIME button Example The current time is 1 30p m The time indication will dis appear automatical...

Страница 14: ...n off time Example If you set 3 hours sleep time at 11 38 p m the turn off time is 2 38 a m Start Sleep timer The device will be turned off by the sleep timer and turned on by on timer 1 Set the ON timer 2 Press the SLEEP button and set the sleep timer For heating In this case the device will turn off in 2 hours at 1 38 a m and turn on earlyso that the preset temperature will be almost reached at ...

Страница 15: ...horizon tal air deflector swings up and down If the button is pressed again the deflector stops in its current position Several seconds about 6 seconds may be required before the deflector starts to move Use the horizontal air deflector within the adjusting rangeshown in the right When the operation is stopped the horizontal air deflector moves and stops at the position where the air outlet closes CAUT...

Страница 16: ...elow Open the front panel carefully and remove the filter Vacuum dust from the air filter using vacuum cleaner If there is too much dust wash the filter with a detergent and rinse it thoroughly After that dry it in the shade 3 Set the filter with FRONT mark facing front and slot them into the original state After attaching the filters push the front panel at three arrow portions as shown in figure and c...

Страница 17: ...ains at indicators or signal receiver of indoor unit it causes trouble Method of removing the front panel Be sure to hold the front panel with both hands to detach and attach it Removing the Front Panel Removing the Front Panel When the front panel is fully opened with both hands push the right arm to the inside to release it and while closing the front panel slightly put it out forward When the f...

Страница 18: ... mode will be displayed Pressing the button while the unit is in operation will let the protective circuit work so that the unit will not operate for approximately 3 minutes During heating operation the indoor unit s color indicator lamp may flash with no air emitted for a while If you feel cold wind during warming operation with the HI fan speed or want to make the unit operation quieter after the...

Страница 19: ...or low Is the circuit breaker ON Is the power plug inserted Do you have any power cut When it does not operate When it does not cool well When it does not heat well The following phenomena do not indicate unit failure Operation start The unit is preparing to blow warm air Please wait In operation The outdoor unit is defrosting Please wait Hissing or fizzy sounds Refrigerant flow noise in the pipe or...

Страница 20: ...tely Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above inspections Inform your agent of the model of your unit production number date of installation Please also inform him regarding the fault Please note On switching on the equipment particularly when the room light is dimmed a slight brightness fluctuation may occur This is of no co...

Страница 21: ...MEMO ...

Страница 22: ...MEMO ...

Страница 23: ...MEMO ...

Страница 24: ... 447 A ...

Отзывы: