– 78 –
PAM (POWER ACTIVE MODULE) CIRCUIT
Phenomenon 1 <Rotation speed does not increase>
Is the DC voltage at least 260V?
Is the OVL lamp lit?
If the lamp is lit, it does not
indicate fault, but the unit
is overload status.
Recheck cord, etc. of the
ACT module. If they are
disconnected, connect
them securely.
If abnormality continues,
replace the ACT module.
Ocervoltage defect: ACT module faulty
(15-times blinking)
Removing the ACT module:
1. Disconnect the connector and remove the 8
receptacles.
< Caution >
The resin sleeve can be removed by pulling it up,
but the PVC sleeve or receptacle without sleeve
cannot be removed this way; remove it by the
procedure on the right. (It cannot be removed
unless the positive lock is released.) Do not pull or
lift it forcibly: this could break PWB or terminals.
2. Remove the 2 (M3) screws.
2
Pull up.
1
Push the hook for
releasing positive lock.
Push the hook with radio
pliers or driver, etc. and
pull it up. It can then be
removed easily.
Yes