– 90 –
LD301 blinks 6 times.
The temperature at the
OH thermistor rises.
Is the thermistor circuit
normal?
Replace parts in the
thermistor circuit.
LD301 blinks 5 times.
Overload lower limit cut.
Replace the control P
.W
.B.
Check to see if the refrigerating cycle is defective.
Check the indoor unit for clogged heat exchanger or filter
.
Check the outdoor unit for defective shielding.
LD301 blinks 4 times.
Failure of switching.
Is the 15V power supply
output normal?
(Power P
.W
.B. display)
Is the intelligent power
module (IPM) normal?
(Inverter section)
The intelligent power module
may be defective.
Replace the control P
.W
.B.
See “System Power
Module Diagnosis”.
With CN3 and CN4
disconnected, is the 15V
output between
“15V” and
”15-0V” on the power
P.
W
.B.?
Replace the power P
.W
.B.
LD301 blinks 3 times.
Abnormal low speed.
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Ye
s
Yes
No
No
No
No
No
No
No
※
※
※
※
Содержание RAC-18YH4
Страница 21: ... 19 GRAM 18YH4 RAC 18YH4 CAUTION The marked parts are very important ones for safety ...
Страница 23: ... 21 RAS 18YH4 MODEL ...
Страница 24: ... 23 RAC 18YH4 MODEL H8 3 0 3 9 AX 8 T 1 0 ...
Страница 27: ... 26 MAIN P W B MARKING ON P W B COMPONENT SIDE SOLDERING SIDE MODEL RAC 18YH4 ...
Страница 29: ... 29 button MODEL RAS 18YH4 BASIC MODE 31 33 33 33 37 35 ...
Страница 35: ... 38 REFRIGERATING CYCLE DIAGRAM MODEL RAS 18YH4 RAC 18YH4 SUCTION TANK SUCTION TANK ...
Страница 99: ...Printed in Japan TSK AW NO 0004E RAS 18YH4 RAC 18YH4 ...