![Hitachi RAC-18YH4 Скачать руководство пользователя страница 85](http://html.mh-extra.com/html/hitachi/rac-18yh4/rac-18yh4_service-manual_139624085.webp)
– 88 –
Communication error
.
LD301 blinks 9 times.
Is the connecting cable
connected properly?
(Is 35V being output on the
indoor unit side?)
Are CN3 and CN4
connected?
Is DC35V being output
between terminals C and D?
Normal: DC32V – 39V
Standby: DC18V – 23V
Is DC35V being output at
both ends of R35?
Connect CN 3 and CN4.
Connect properly
.
Replace the power P
.W
.B.
• Defective SW power supply
Replace the power P
.W
.B.
• NF coils, IF coils, etc.
may be broken.
Check the interface circuit
and replace the control
P.
W.
B. if needed.
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Содержание RAC-18YH4
Страница 21: ... 19 GRAM 18YH4 RAC 18YH4 CAUTION The marked parts are very important ones for safety ...
Страница 23: ... 21 RAS 18YH4 MODEL ...
Страница 24: ... 23 RAC 18YH4 MODEL H8 3 0 3 9 AX 8 T 1 0 ...
Страница 27: ... 26 MAIN P W B MARKING ON P W B COMPONENT SIDE SOLDERING SIDE MODEL RAC 18YH4 ...
Страница 29: ... 29 button MODEL RAS 18YH4 BASIC MODE 31 33 33 33 37 35 ...
Страница 35: ... 38 REFRIGERATING CYCLE DIAGRAM MODEL RAS 18YH4 RAC 18YH4 SUCTION TANK SUCTION TANK ...
Страница 99: ...Printed in Japan TSK AW NO 0004E RAS 18YH4 RAC 18YH4 ...