– 29 –
MODEL
RAC-18G5
COMPRESSOR MODEL
ASH210SV-C8LU
PHASE
SINGLE
RATED VOLTAGE
220 ~ 230 V
RATED FREQUENCY
50 Hz
LOCKED ROTOR CURRENT
40 A
POLE NUMBER
2
COMPRESSOR MOTOR
Compressor Motor Speci
fi
cations
CONNECTION
20°C
(68°F)
75°C
(167°F)
( )
RESISTANCE VALUE
!
CAUTION
When the Air Conditioner has been operated for a long time with the capillary tubes clogged or crushed
or with too little refrigerant, check the color of the refrigerant oil inside the compressor. If the color has
been changed conspicuously, replace the compressor.
EXTERNAL OVERLOAD RELAY
INTERNAL PROTECTOR
NO
YES
RM = 1.69
RA = 1.54
RM = 2.06
RA = 1.87
Содержание RAC-18G5
Страница 29: ... 27 MODEL RAC 18G5 ...
Страница 33: ... 31 CIRCUIT DIAGRAM Remote Control ...
Страница 34: ... 33 PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAS 18G5 ...
Страница 35: ... 35 BLOCK DIAGRAM MODEL RAS 18G5 RAC 18G5 ...
Страница 39: ... 43 REFRIGERATING CYCLE DIAGRAM MODEL RAS 18G5 RAC 18G5 ...
Страница 51: ... 55 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 18G5 ...
Страница 53: ...PM NO 0485E Made in Malaysia RAS 18G5 RAC 18G5 ...