- 34 -
Basic Heating Operation
Notes:
(1)
Condition for entering into Hot Dashed mode. When fan set to
“Hi” or “Auto mode” and i) Indoor temperature is lower than 18
℃
,
and ii) outdoor temperature is lower than 10
℃
,
and iii) Temperature difference between indoor temperature and set temperature has a corresponding compressor speed (calculated
value in Table 3) larger than WMAX.
(2)
Hot Dashed will release when i) Room temperature has achieved the set tempe SFTDSW. ii) Thermo off.
(3)
During Hot Dashed operation, thermo off temperature is set temperature (with shift value) +3
℃
.
After thermo off, operation continue in Fuzzy control mode.
(4)
Compressor minimum “ON” time and “OFF” time is 3 minutes.
(5
)
During normal heating mode, compressor maximum speed WMAX will maintain for 120 minutes if indoor temperature is higher than 1
8
℃
.No time limit constrain if outdoor temperature
is lower than 2
℃
or indoor temperature is lower than 18
℃
.
(6)
During Hotkeep or Defrost mode, indoor operation lamp will blink at interval of
(7)
When heating mode starts, it will enter into Hotkeep mode if indoor heat exchanger temperature is lower than YNEOF + 0.33
℃
.
(8)
When fan is set to “Lo”, compressor speed will be limited to WBEMAX. When fan is set to "Med", compressor speed will be lim
ited to WJKMAX.
When fan is set to “Silent”,
compressor rpm will be limited to WSZMAX.
(9)
In “Ultra-Lo” fan mode, if indoor temperature is lower than 18
℃
,
indoor fan will stop. If indoor temperature is higher than 18
℃
+ 0.33
℃
,
fan will continue in “Ultra-Lo” mode.
During Hotkeep or Defrost mode, fan will continue in “Ultra-Lo” mode.
(10)
During Hot Dashed, when room temperature reaches set tempe SFTDSW compressor speed is actual speed x DWNRATEW.
Temperature
Calculated
difference
compressor speed
1.66
℃
1900
10JH1
14JH1
min
–
1
2.00
℃
2400
min
–
1
2.33
℃
2900
min
–
1
2.66
℃
3400
min
–1
3.00
℃
3.33
℃
3.66
℃
3800
min
–1
1900 min
–1
2400
min
–1
2900
min
–1
3400
min
–1
3900
min
–1
3800
min
–1
4400
min
–1
3800
min
–1
4500
min
–1
Table 3 Compressor speed
2 seconds “ON” and 1 second “light reducing” .
1.33
℃
0.66
℃
10sec.
60sec.
WMAX2
Hi
Lo
15sec.
15sec.
15sec.
Lo
Lo
Lo
15sec.
15sec.
3min.
Lo
(with shift value)
(W
M
A
X)
(W
S
T
D)
0
W
td
1
W
td
2
(W
M
A
X
2)
3000
SFTDSW
WMIN
Indoor fan
Operarion lamp
Ultra-Hi
Hi
Med
Lo
Silent
Ultra-Lo
Max.
Rating
Min.
Outdoor fan
Start/Stop button
Thermo judgment
Defrost signal
Preheating judgment
Heating set temperature
(remote control set temperature
(+))
Fan speed set to "auto"
Start
Max.3 min.
Preheating released
Preheating released
Control by heat exchanger temperature
Control by heat exchanger temperature
Control by
heat exchanger temperature
Control by
heat exchanger temperature
Control by
heat exchanger temperature
Thermo OFF
Thermo
OFF
Thermo
OFF
Stop
Start
Stop
Start
Stop
Compressor speed
Dashed period
td
20min.
Reversing valve
(Cooling "ON" mode)