– 7 –
MODEL RAS-14G5 / RAC-14G5
Figure showing the installation of Indoor and Outdoor unit
In case the pipe length is more than 8m, add refrigerant R410A at 10 gram per every meter exceeds. However, pipe
length shall not exceed 15m.
CAUTION
!
●
The difference in height
between the indoor and
outdoor unit should be kept
max 5m.
●
The connecting pipe, no
matter big or small, should
all be insulated with insulation
pipe and then wrapped with
vinyl tape. (The insulator will
deteriorate if it is not wrapped
with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commercial products).
Be sure to
completely
seal any gap.