– 45 –
●
The air defl ector control operation shown below is done when the swing switch is pressed or
when the operation mode is changed.
●
The air defl ector control operation shown below is done when the operation switch is turned off.
Item
3-way
AUTO (Swing)
Specifi cation
Cooling/
dehumidi-
fying
Air
blowing
direction
control
8
●
Operation starts in advance so that the room temperature reaches the preset value at
the set time.
●
The operation time is obtained as follows depending on the room temperature when
operation starts.
(1) Calculation method of the moved-up time.
Moved-up time (MT) = Moved-up time depending on the temperature difference (OT) +
compensation time (HT).
MT is at least 1 minute if OT is not zero.
Cooling
(MT)
00 ~ 60 min.
(OT)
00 ~ 60 min.
(HT)
–60 ~ 60 min.
Obtain OT (moved-up time depending on the temperature difference) from the table below.
7
“NICE
TEMPERA-
TURE”
reservation
Cooling
Setting temp. – Room temp. Time (min.)
00.00
–
02.00
00
02.25
–
05.00
15
05.25
–
08.00
30
08.25
–
11.00
45
11.25
–
60
❈
The preset temperature value shown above does not include any shift value.
(2) Compensation
1 The “Attained” state is monitored and a “Not attained” check is done to revise the
compensation time (HT).
“Attained” monitor
Continuously monitored during “NICE TEMPERATURE” operation.
(Cooling)
When the room temperature < Set value + compensation shift, it’s operated same
as above.
“Not attained” check
Performed once when the “NICE TEMPERATURE” timer is completed.
(Cooling)
When the room temperature > Set value + compensation shift +1°C, it’s operated
same as above.
❈
If the room temperature is 1°C from the set value + compensation shift,
compensation is not done.
Содержание RAC-10G5
Страница 31: ... 30 MODEL RAC 10G5 RAC 14G5 ...
Страница 35: ... 34 WIRING DIAGRAM MODEL RAS 10G5A1 ...
Страница 36: ... 35 WIRING DIAGRAM MODEL RAS 14G5AC 63CHA1 ...
Страница 37: ... 37 CIRCUIT DIAGRAM Remote Control ...
Страница 38: ...PRINTED WIRING BOARD LOCATION DIAGRAM MODEL RAS 10G5 14G5 RAC 10G5 14G5 39 ...
Страница 39: ... 41 BLOCK DIAGRAM MODEL RAS 10G5 14G5 RAC 10G5 14G5 ...
Страница 42: ... 46 REFRIGERANT CYCLE DIAGRAM MODEL RAS 10G5 RAC 10G5 RAS 14G5 RAC 14G5 ...
Страница 50: ... 54 ...
Страница 56: ... 60 PARTS LIST AND DIAGRAM INDOOR UNIT MODEL RAS 10G5 14G5 ...
Страница 59: ... 63 PARTS LIST AND DIAGRAM OUTDOOR UNIT MODEL RAC 10G5 14G5 ...
Страница 62: ...HITACHI PM NO 0487E Printed in Malaysia RAS 10G5 RAC 10G5 RAS 14G5 RAC 14G5 ...