Содержание PC-P1HE

Страница 1: ...arde este manual para referência futura Læs denne vejledning grundigt inden du tager af fjernbetjening Gem vejledningen til fremtidige opslag Lees deze handleiding goed door voordat u de fjärrkontroll gebruikt Bewaar de handleiding voor later gebruik Läs denna handbok noga innan externe bediening används Spara handboken för framtida bruk ÄéáâÜóôå ðñïóåêôéêÜ áõôü ôï åã åéñßäéï ðñéí ôç ñÞóç ôïõ åéñé...

Страница 2: ......

Страница 3: ...VARSEL Farer eller farlig brug som KAN resultere i alvorlig personskade eller dødsfald WAARSCHUWING Gevaren of onveilige praktijken die ernstig persoonlijk letsel of de dood tot gevolg KUNNEN hebben VARNING Risker eller osäkra tillvägagångssätt som KAN leda till svåra personskador eller dödsfall ΠΡΟΕΙ ΟΠΟΙΗΣΗ Κίνδυνοι ή επικίνδυνες πρακτικές οι οποίες ΜΠΟΡΕΙ να έχουν ως αποτέλεσµα σοβαρές σωµατικέ...

Страница 4: ... CONTROLLO 5 IMPOSTAZIONE OPZIONALE E IMPOSTAZIONE DI INPUT OUTPUT DELL UNITÀ INTERNA PARTE I FUNCIONAMENTO 1 RESUMO DA SEGURANÇA 2 TRABALHO DE INSTALAÇÃO 3 LIGAÇÕES ELÉCTRICAS 4 PROCEDIMENTOS DE VERIFICAÇÃO 5 AJUSTE OPCIONAL E AJUSTE DE ENTRADA SAÍDA DE UNIDADE INTERIOR INDHOLDSFORTEGNELSE INHOUDSOPGAVE DEL I BETJENING 1 OVERSIGT OVER SIKKERHED 2 MONTERINGSARBEJDE 3 ELEKTRISK LEDNINGSFØRING 4 KON...

Страница 5: ...service contractor of HITACHI DO NOT modify the electrical wiring It may cause serious accidents CAUTION DO NOT install the controller and cable at such places as where there is oil vapor and the oil is dispersed where the hot springs are near in a sulfuric environment where generation flowing staying or leaking of flammable gas is detected where the sea is near in the salty environment an acid or...

Страница 6: ...tion place of the controller with the customer s acceptance Especially in case that a remote control thermostat is used select the installation place in consideration with the following points where the average room temperature can be detected where the children can t touch where the thermostat is not exposed directly to the sun where the heat sources is not near around where the thermostat is not...

Страница 7: ...ne keep a distance more than 50 mm between the controllers vertically If the distance is insufficient the front cover of the controller can not open wide enough 2 4 INSTALLATION PROCEDURE 1 Insert the edge of the flat head screwdriver into the dent parts at the bottom of the holding bracket push and turn the screwdriver and remove the controller from the holding bracket as shown in the next figure...

Страница 8: ...nto the wall as shown below 2 Attach the stopper to the cable at the inside of the draw out hole 3 Lead the cable with its sheath peeled through the groove 4 Peel the insulation at the end of the cable and clamp the M3 solderless terminals Cable Band Field Supplied REMOCON A B REMOCON Fix the holding bracket with the mark UP upward Screw Accessory ...

Страница 9: ...ion at the end of the cable and clamp the M3 solderless terminals Mounting procedures 1 Insert the hooks of the controller to the holes on the top of the holding bracket 2 Push the lower part toward the holding bracket 3 When the click sound is heard the controller is attached to the holding bracket and the mounting work is finished CAUTION Pay attention so that the cable may not be slack If the c...

Страница 10: ...is remote control switch can control sixteen units as the maximum In case of this modification wiring connection and other works shall be performed as indicated in the following procedures Two Remote Controls can be connected in the same unit or unit groups The second one is Subsidiary Remote Control Switch as indicated below Check Chapter 5 for more information Controller Ring core Band Controlle...

Страница 11: ...le Model Length m 7E790211 PRC 10E1 10 7E790212 PRC 15E1 15 7E790213 PRC 20E1 20 7E790214 PRC 30E1 30 CAUTION Use the twist shield pair cable 2 x 0 75mm as transmitting wire cable for prevention of the malfunction The total cable length is max 500m When the total cable length is within 30m other type cable more than 0 3mm can be used Keep a distance more than 30 cm between the remote control cable...

Страница 12: ...d units is indicated on the liquid crystal display In case that the indicated number is not correct some abnormalities exist incorrect wiring the electric noise etc Turn OFF the power supply and correct the wiring after checking the following points Do not repeat turning ON and OFF within 10 seconds Power Supply for Indoor Unit is Not Turned ON or Incorrect Wiring Incorrect Connection of Connectin...

Страница 13: ...ET TEMP SERVICE is indicated and the mode number is flickered The address of the indoor unit ADDS to set and the refrigerant cycle number RN are indicated by 0 15 The left figure shows the No 1 cycle and No 1 indoor unit NOTE 1 In case that the both indications of the ADDS and RN show AA the same setting is performed to all the indoor units 2 The address of indoor unit not connected is not indicat...

Страница 14: ... 00 Standard 01 Fixed b7 Fixing Cooling Operation N 00 Standard 01 Fixed b8 Automatic Cooling Heating Operation N 00 Not Available 01 Available b9 Fixing Fan Speed N 00 Standard 01 Fixed C1 Not Prepared Not Used C2 Not Prepared Not Used C3 Not Prepared Not Used C4 Drain Pump Operation in Heating A 00 Not Available 01 Available C5 Increasing Fan Speed A Not Used C6 Increasing Fan Speed When Thermo ...

Страница 15: ...d d3 Power Supply ON OFF 2 A 00 Not Available 01 Available E1 Ventilation Mode A 00 02 3 E2 Operation To Increase Air Volume for Ventilation A 00 Not Available 01 Available E3 Not Prepared Not Used E4 Cool Down Warm Up Period A 00 02 4 E5 F1 Not Prepared Automatic Setting of OFF Timer N Not Used 00 24 0 24 Hours F2 Remote Control Main Sub Setting N 00 Main 01 Sub 2 01 Changing from Indoor Thermist...

Страница 16: ...m Thermostat for Cooling Operation 02 Room Thermostat for Heating Alarm 03 Remote ON OFF 1 Cooling 04 Remote ON OFF 2 Operation Thermo ON for Cooling 05 Remote ON OFF 2 Stoppage Heating 06 Forbidding Remote Control after Manual Stoppage Thermo ON for Heating 07 Remote Cooling Heating Change Total Heat Exchanger 08 Not Set Not Set ÔATTENTION Write down the contents of the setting in the table print...

Страница 17: ......

Страница 18: ...PMML0049 A 08 03 Printed in China ...