INSTALLATION MANUAL
Liquid crystal display (LCD)
DAY
SCHEDULE
SELECT
LOUVER
VENTI
MODE
FAN SPEED
TIMER
RESET
OK
Model: PC-ART
Fan speed indicator
Indicates the ventilation speed selected:
- (High / Medium / Low)
Indicator of Total ventilator
Indicates if the total heat exchanger has been selected.
- A/C
only air conditioning
- VENTI
only ventilation
- A/C + VENTI
if both are selected
!
Operation Mode Indicator
Indicates the operation mode selected:Fan/Cool/Heat/Dry/Auto
(Cool/Heat)
"
Run indicator (Red lamp)
#
RUN/STOP switch
$
MODE (Operation Mode Selection) switch
%
FAN SPEED (Fan Speed Selection) switch
&
Up & down panel operation switch
'
VENTI (ventilator operation) switch
(
LOUVER (de
ß
ector panel) switch
)
SELECT (Day/Schedule) switches
Increase and decreases the Day/Schedule for timer operation.
*+
ON/OFF TIMER switch
Used to activate or deactivate the timer operation.
,
OK switch
-+
RESET (Filter Reset Switch)
After cleaning the air
Þ
lter, press the “RESET” button. FILTER
indication will disappear and the next
Þ
lter cleaning time is reset. It
also stops the run procedure.
.
TEMP (temperature setting) switches
/+
T.RUN (test run indication)
Check (check indication)
These tests appear when TEST RUN or CHECK are being
performed.
0
ABNML (alarm) indicator
1
SET TEMP (set temperature) indicator
2+
1234S indicator (setting schedule number)
3
Mon Tue ... Sun indicator (day of the week indicator).
Indicates that central station or CSNet control is operating.
4
Swing louver indicator
DEFROST indicator
5+
SERVICE mode indicator
.
Indicates the change to special operations
6+
Time indicator.
7+
Time indicator
. (Indicates the programmed time).
To open the cover, pull in
the direction of the arrow.
8
NOTE:
-
If the LOW fan speed is selected and the outdoor
temperature is higher than 21°C, the compressor is
subjected to an excessive load when operating in heating
mode.
Therefore, the fan speed should be set to HIGH or
MEDIUM to avoid activating the safety devices.
-
When the system is restarted after a shutdown of more
than approximately 3 months, the system should be
checked by your service provider.
-
Turn off the main switch when the system is to be
inoperative for a long period of time. Otherwise the system
consumes electricity as the oil heater remains active even
though the compressor is stopped.
4 REMOTE CONTROLLER OPERATION
4.1. OPTIONAL LIQUID CRYSTAL REMOTE CONTROL PC-ART