Fault messages
6.2.1-1
Faults causing ink stoppage
* After cleaning, thor-
oughly wipe off the
makeup ink from the
surfaces of the com-
ponents with a piece
of wiping paper. Then,
dry the surfaces.
No.
Message
Meaning of message
Remedy
1
Ink Low
The ink level in the ink
tank is too low. (If ink is not
added or replaced within
60 minutes after
indication of the warning,
the printer comes to a stop
with the warning condition
replaced by a fault
condition.)
z
Add ink to the ink tank.
2
Ink Over Fill
The ink level in the main
ink tank is too high.
z
Drain ink from main ink
tank drain tube
3
Makeup Ink
The makeup ink level in
the makeup ink tank is too
low (if replenishment is
not performed within
60 minutes after
indication of the warning)
z
Add makeup ink to the
makeup ink tank.
4
Replenishment Time-out
The automatic
replenishment sequence
is taking too much time.
z
Contact your nearest
Hitachi distributor.
5
Ink Drop Charge Too Low
The ink particles are
poorly charged (charge
too low).
z
Clean the gutter,
deflection electrode,
and adjacent parts.
z
Adjust the excitation
setting to make sure
that the ink particles
are properly shaped.
z
Adjust the ink pres-
sure.
6
No Ink Drop Charge
The particles are not
charged electrically.
z
Check if the ink beam
is positioned approxi-
mately in the center of
the gutter.
z
Clean the gutter,
deflection electrode,
and adjacent parts.
z
Adjust the excitation
setting to make sure
that the ink particles
are properly shaped.
z
Check the ink pres-
sure.
7
Noise fault C
The controller section
malfunctioned due to
noise.
z
Turn the power OFF
and then back ON.
8
Noise fault M
Malfunction of the engine
section caused by noise.
z
Turn OFF the power
and then turn back
ON.
Содержание PB Series
Страница 10: ...x ...
Страница 36: ...2 12 z 2 2 Shutdown Section 2 ...
Страница 64: ...3 28 z 3 7 Recalling Saved Data Section 3 ...
Страница 78: ...4 14 z 4 5 Controlling the Executable Functions Section 4 ...
Страница 100: ...6 10 z 6 3 Viewing the Warning Condition and Fault Occurrences Section 6 ...
Страница 102: ...7 2 z Emergency Procedures Section 7 ...
Страница 108: ...8 6 z 8 3 Parts to be replaced periodically Section 8 ...