4-25
Chapter 4
Safety Function
e.g. Case: SS1-A then SBC-A activating after STO-A
activating
[1-31]SBC-A Time linkage=02( SS1, then SBC after STO), [1-
22]SS1-A monitoring method=00(time),
[1-12]STO-A Release mode =01(With safety signal) and [1-
36]SBC-A release level=0.00%:
e.g. Case: SS1-A, then SBC-A activating after STO-A
activating
[1-31]SBC-A Time linkage=02(SS1 then, SBC after STO), [1-
22]SS1-A monitoring method= 01(frequency), [1-12]STO-A
Release mode = 01(With safety signal) and [1-36]SBC-A
release level=0.00%:
SBC-A
Input
Output
STO-A monitoring
Motor speed
SBC-A control
Open
Short
STO-A completed
Active
Inactive
Active
Inactive
Inactive
Active
Releasable
[1-11]STO-A Keep time
[1-32]Wait time for SBC-A after STO-A
[1-35]SBC-A STO-A Release wait time
[1-34]SBC-A frequency
[1-23]SS1-A Active time
SBC-A
Input
Output
STO-A monitoring
Motor speed
SBC-A control
Open
Short
[1-34]SBC-A frequency
STO-A completed
Active
Inactive
Active
Inactive
Inactive
Active
Releasable
[1-26]SS1-A Wait time
[1-24]SS1-A Min Deceleration time
[1-25]SS1-A Max Deceleration time
[1-32]Wait time for SBC-A after STO-A
[1-11]STO-A Keep time
[1-35]SBC-A STO-A Release wait time
Содержание P1
Страница 2: ...The picture is an example of installing P1 FS to SJ P1 ...
Страница 8: ...C 3 Index Memo ...
Страница 10: ...1 2 Chapter 1 Safety Precaution Risk Memo ...
Страница 12: ...2 2 Chapter 2 Introduction to the Safety Function Guide Memo ...
Страница 62: ...7 2 Chapter 7 Commissioning Memo ...
Страница 64: ...8 2 Chapter 8 Verification and Validation Memo ...
Страница 68: ...10 2 Chapter 10 Maintenance Memo ...
Страница 72: ...11 4 Chapter 11 Specification and Technical data Memo ...