English
— 14 —
(4) Without touching the trigger, depress the
push lever against the workpiece.
Pull the trigger.
䡺
THE NAILER MUST OPERATE.
(5) With the Nailer off the workpiece, pull the
trigger.
Depress the push lever against the
workpiece.
䡺
THE NAILER MUST OPERATE.
(6) If no abnormal operation is observed, you
may load nails in the Nailer.
Drive nails into the workpiece that is the
same type to be used in the actual
application.
䡺
THE NAILER MUST OPERATE
PROPERLY.
ADJUSTING AIR PRESSURE
WARNING
䢇
Do not exceed 120 psi (8.3 bars 8.5 kgf/
cm
2
).
Adjust the air pressure at recommended
operating pressure 70 – 120 psi (4.9 – 8.3 bar
5 – 8.5 kgf/cm
2
) according to the length of
nails and the hardness of workpiece.
The correct air pressure is the lowest
pressure which will do the job. Using the
Nailer at a higher than required air pressure
unnecessarily over stresses the Nailer.
LOADING NAILS
WARNING
䢇
When loading nails into Nailer,
1) do not pull trigger;
2) do not depress push lever; and
3) keep Nailer pointed downward.
<NV45AB2>
(1) Grip the nail guide and knob with your
fingers. Press the knob down and swing
the nail guide open. Then open the
magazine cover.
(2) Adjust the position of the nail holder
according to the nail length.
The nail will not feed smoothly if the nail
holder is not correctly adjusted.
1
Turn the nail holder about 90 degrees
counterclockwise.
2
Move the nail holder up and down to
align the plate of the nail holder with
a mark on the magazine in accordance
with the length of the nails being
used.
3
Turn the nail holder 90 degrees
clockwise until you hear "click".
Do not pull Trigger
Depress
Push Lever
Nail Guide
Knob
Magazine
Cover
01Eng_NV45AB2_US