English
— 13 —
TESTING THE NAILER
DANGER
䢇
Operators and others in
work area MUST wear
safety glapsses with
side shields which
conforms to ANSI Z87.1
specifications.
WARNING
䢇
Never use Nailer unless push lever is
operating properly.
Before actually beginning the nailing work,
test the Nailer by using the checklist below.
Conduct the tests in the following order.
If abnormal operation occurs, stop using the
Nailer and contact a Hitachi authorized
service center immediately.
(1) DISCONNECT AIR HOSE FROM NAILER.
REMOVE ALL NAILS FROM NAILER.
䡺
ALL SCREWS MUST BE TIGHTENED.
If any screws are loose, tighten them.
䡺
THE PUSH LEVER AND TRIGGER
MUST MOVE SMOOTHLY.
(2) Adjust the air pressure to 70 psi (4.9 bars
5 kgf/cm
2
).
Connect the air hose.
Do not load any nails in the Nailer.
䡺
THE NAILER MUST NOT LEAK AIR.
Hold the Nailer downward and pull the
trigger.
䡺
THE NAILER MUST NOT OPERATE.
(3) With finger off the trigger, depress the
push lever against the workpiece.
䡺
THE NAILER MUST NOT OPERATE.
Trigger
Do not
connect
air hose
Push Lever
Pull Trigger