Performing Universal Volume Manager Operations
5-5
Hitachi Universal Storage Platform V/VM Universal Volume Manager User’s Guide
Caution:
Do not specify 01 for the LDKC number when you map a volume of
which the emulation type is 3380 series except for 3380-3, 3380-3A, 3380-
3B, 3380-3C. Before you apply the mapping configuration, make sure the
LDKC number which is automatically assigned is 00.
Note:
Before you map the external volume, check whether any application
(for example, Command Control Interface) is using the command device. If
there is, stop the application.
To map the external volume automatically:
1.
Start Storage Navigator, and open the Volume Operation window.
2.
Make sure that Storage Navigator is in Modify mode.
3.
Right-click one of the following in the Volume Operation tree:
–
Subsystem
: Allows you to create a new path group, and add external
volumes to the new path group.
–
Path group: Allows you to add external volumes to the existing path
group.
4.
Click
Add Volume (Auto)
in the pop-up menu and click the desired
mapping policy in the submenu.
–
When you click the
Subsystem
in the Volume Operation tree, the
Configure Cross-subsystem Paths dialog box is displayed. Go on to step
5.
–
When you click the path group in the Volume Operation tree, the
Volume Discovery is executed and all the external volumes found by the
Volume Discovery are displayed in
blue italics
in the Volume Operation
window. Go on to the step 7.
5.
Configure cross-subsystem paths in the Configure Cross-subsystem Paths
dialog box.
Configure at least two cross-subsystem paths and change the priority if
necessary.
6.
Click
OK
to close the Configure Cross-subsystem Paths dialog box.
You are returned to the Volume Operation window. The Volume Discovery
is executed, and all the external volumes found by the Volume Discovery
are mapped. The settings are displayed in
blue italics
.
7.
Verify the settings in the Preview dialog box.
8.
Click
Apply
in the Volume Operation window.
The settings are applied to the local storage system and the Volume
Operation window is displayed normally. When an error occurs, an error
message is displayed. Verify the details in the Preview dialog box.
Содержание MK-96RD626-07
Страница 8: ...viii Contents Hitachi Universal Storage Platform V VM Universal Volume Manager User s Guide ...
Страница 16: ......
Страница 160: ...7 10 Remote Command Devices Hitachi Universal Storage Platform V VM Universal Volume Manager User s Guide ...
Страница 186: ...A 20 Connecting External Storage Systems Hitachi Universal Storage Platform V VM Universal Volume Manager User s Guide ...
Страница 198: ...C 4 Adjusting Volume Capacities for Pairs Hitachi Universal Storage Platform V VM Universal Volume Manager User s Guide ...
Страница 202: ...Index 2 Index Hitachi Universal Storage Platform V VM Universal Volume Manager User s Guide ...
Страница 203: ......
Страница 204: ......