6 MAINTENANCE
6-17
Figure 6-5 Example of Optical Transmitting Level Measurement
Take care when handling the optical fiber cable. In particular, do not make
the bend radius smaller than 30 mm, otherwise a wipe breaking may be
caused.
After measurement, clean the optical module and the optical connector.
Since the optical fiber connector of the OD.RING (LQE010) is the FC type
(SMA type for the LQE015), the optical power meter must be applicable to the
FC type (or SMA type). Use the connector adapter (attached to the optical
power meter or separately sold) for the FC type (or the SMA type).
LQE010
OD.RING
ERR
RX
TX
MODU.
NO
PR
SR
CPL
NO
ERR
RX
TX
TX
RX
TX
RX
PR
SR
LQE010
OD.RING
ERR
RX
TX
MODU.
NO
PR
SR
CPL
NO
ERR
RX
TX
TX
RX
TX
RX
PR
SR
Short optical fiber
cable
(1 m or less)
LQE010
OD.RING
ERR
RX
TX
MODU.
NO
PR
SR
CPL
NO
ERR
RX
TX
TX
RX
TX
RX
PR
SR
Disconnect
Connector adapter
(attached to the optical
power meter or separately
sold)
FC type (LQE010)
SMA type (LQE015)
Optical power meter
Wavelength: 850nm (LQE010)
880nm (LQE015)