87
Commands
Control Description
Parameter or Response
ERST ?
Error Status inquiry
1st byte: Refers to Fan error; one of 0 to 2
2nd byte: Refers to Laser error; one of 0 to 2
3rd byte: Refers to Temperature error; one of 0 to 2
4th byte: Refers to Cover error; one of 0 to 2
5th byte: Refers to Filter error; one of 0 to 2
6th byte: Refers to Other error; one of 0 to 2
The meaning of 0 to 2 is as given below
0 = Error is not detected
1 = Warning 2 = Error
LAMP ?
Laser Status inquiry
1st number (digits 1 to 5): Laser Hours
2nd number : 0 = Lamp off, 1 = Lamp on
INST ?
Input Source List inquiry
11 12 31 32 33 36 37
NAME ?
Projector Name inquiry
Responds with the name set in the item
PROJECTOR NAME of the NETWORK menu
INF1 ?
Manufacturer's Name
inquiry
HITACHI
INF2 ?
Model Name inquiry
LP-WU9750B
INFO ?
Other Information inquiry Responds with the factory information and so on
CLSS ?
Class Information inquiry
1
NOTE
• The password used in PJLink
TM
is the same as the password set
in the Web Control. To use PJLink
TM
without authentication, do not set any
password in Web Browser Control.
• For specifications of PJLink
TM
, see the web site of the Japan Business
Machine and Information System Industries Association.
URL: http://pjlink.jbmia.or.jp/