![Hitachi KP-M1A series Скачать руководство пользователя страница 15](http://html.mh-extra.com/html/hitachi/kp-m1a-series/kp-m1a-series_operation-manual_140925015.webp)
KP-M1A
- 14 -
8-1 ONE trigger mode
The shutter is started by the rising edge of the trigger A pulse, and V.SYNC is reset by the falling edge
of the trigger A pulse. (After reset, the first field is delivered)
A shutter time is controlled by the duration when the trigger pulse is high.
Only one field image is delivered by one trigger pulse, and a sync signal lasts till the next pulse.
Trigger pulse
* 5Vp-p +0.5/-1.0Vp-p
* Low period:
EIA: 16.7ms or more
CCIR: 20ms or more
* High period: 8us or more
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com